EasyManua.ls Logo

MAAX Spas Powerpool - Changing Modes; Time and Filtration Cycles; Setting the Time; Preset Filter Cycles

MAAX Spas Powerpool
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
19
PowerPool
press the TIME button then press the MODE/
PROG button. The hour digit(s) will be ashing
on the LCD window. Press the WARM or COOL
button to advance the hours up or down to
the desired set point. Press the
MODE/PROG button to enter the time hour.
The minute digits will now be ashing on
the LCD window. Press the WARM or COOL
button to advance the minutes up or down to
the desired set point. Press the MODE/PROG
button to enter the time minutes. At this
point you can either proceed with setting the
ltration cycles as described in the following
‘Changing Filter Cycle’ section, or press the
TIME button to save the settings and exit the
programming sequence.
Preset Filter Cycles
Once the time of day has been set, your
PowerPool™ will automatically lter the water
for a 2-hour period every 12 hours.
The rst lter cycle comes preset to operate
from 8:00AM to 10:00AM, and the second
lter cycle comes preset to operate from
8:00PM to 10:00PM. The F1 indicator light
will be lit whenever the PowerPool™ is in the
rst lter cycle. The F2 indicator light will be
lit whenever the PowerPool™ is in the second
lter cycle. During a lter cycle, the primary
ltration pump will operate in low speed and
can not be turned o unless the PowerPool™ is
put into the Standby mode. At the beginning
of each ltration cycle, the other equipment in
the PowerPool™ will turn on for 30 seconds to
purge all plumbing lines and ensure complete
ltration.
Changing Filter Cycles
The control system allows you to adjust the
start time and duration of each lter cycle
independently to best suit your schedule.
can be immediately reverted back into the
Economy mode at any time by simply pressing
the MODE/PROG button.
Sleep Mode heats the PowerPool™ to within
52°F (11°C) of the set temperature only
during lter cycles. The ‘SLEEP’ icon will be
displayed in the LCD window when this mode
is selected.
Changing Modes
To change the operating mode, press the
MODE/PROG button. The operating mode
will be ashing on the LCD window. Press the
COOL button to cycle through to the desired
mode, and then press the MODE/PROG
button to conrm selection. Pressing WARM
or COOL then JETS2 will put the PowerPool™
into the Standby Mode. While in this mode,
all PowerPool™ functions are temporarily
suspended to allow for lter changes or other
routine maintenance tasks. Press any button
to exit the Standby mode.
Note: Always put your PowerPool™ into
Standby Mode whenever cleaning or
changing your lters.
Time and Filtration Cycles
The control system on your PowerPool™ has
been designed to function properly and safely
at 40°C after connecting the electrical wires
and installing the proper grounds. To take full
advantage of the unique capabilities of your
new PowerPool™, you should rst set the time
and establish your ltration cycles.
Setting the Time
When the time of day has not been
programmed, the TIME’ icon will be ashing
on the LCD window. To set the time of day, rst

Related product manuals