24
24
PowerPool™
If the LCD
displays...
LF
drY
dr
SnA
SnB
SnS
Indicates...
Water ow
problem
- Persistent
ow problem
No water to
the heater
Lack of water
to the heater
Heater sensor A
not functioning
Heater sensor B
not functioning
Heater sensors
are out of
balance
What happens...
Heater will shut down
while PowerPool™
continues to function
normally
PowerPool™
functions will
shut down
Heater will shut
down, otherwise
PowerPool™ con-
tinues to function
normally
PowerPool™
automatically
deactivated
PowerPool™
automatically
deactivated
Possible cause...
- Plugged lter
- Low water
- Slice valves closed
- Block suction returns
- Blocked filter/ skimmer
- Slice valves closed
- Block suction returns
- Blocked filter/ skimmer
- Non-functioning
sensor
- Non-functioning
sensor
Corrective action...
- Remove lter and clean -
- Add water
- Contact dealer
- Open valves
- Remove blockage
- Contact dealer
- Open valves
- Remove blockage
- Contact dealer
- Contact dealer for
replacement sensor
- Contact dealer for
replacement sensor
- Contact dealer
Common LCD Messages
The following table denes other messages you will frequently see on the LCD display:
Message... What it is... What it means...
Pr Priming mode PowerPool™ is in normal Priming Mode operation
SLP Sleep mode PowerPool™ is in normal Sleep Mode operation
Ecn Economy mode PowerPool™ is in normal Economy Mode operation
Std Standard mode PowerPool™ is in normal Standard Mode operation
ICE Freeze condition Pump and Heater will come on to keep water above 45°F
- - Water temperature Current water temperature not measured