EasyManua.ls Logo

MAAX Spas Powerpool - Common LCD Messages

MAAX Spas Powerpool
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
24
PowerPool
If the LCD
displays...
LF
drY
dr
SnA
SnB
SnS
Indicates...
Water ow
problem
- Persistent
ow problem
No water to
the heater
Lack of water
to the heater
Heater sensor A
not functioning
Heater sensor B
not functioning
Heater sensors
are out of
balance
What happens...
Heater will shut down
while PowerPool™
continues to function
normally
PowerPool™
functions will
shut down
Heater will shut
down, otherwise
PowerPool™ con-
tinues to function
normally
PowerPool™
automatically
deactivated
PowerPool™
automatically
deactivated
Possible cause...
- Plugged lter
- Low water
- Slice valves closed
- Block suction returns
- Blocked filter/ skimmer
- Slice valves closed
- Block suction returns
- Blocked filter/ skimmer
- Non-functioning
sensor
- Non-functioning
sensor
Corrective action...
- Remove lter and clean -
- Add water
- Contact dealer
- Open valves
- Remove blockage
- Contact dealer
- Open valves
- Remove blockage
- Contact dealer
- Contact dealer for
replacement sensor
- Contact dealer for
replacement sensor
- Contact dealer
Common LCD Messages
The following table denes other messages you will frequently see on the LCD display:
Message... What it is... What it means...
Pr Priming mode PowerPool™ is in normal Priming Mode operation
SLP Sleep mode PowerPool™ is in normal Sleep Mode operation
Ecn Economy mode PowerPool™ is in normal Economy Mode operation
Std Standard mode PowerPool™ is in normal Standard Mode operation
ICE Freeze condition Pump and Heater will come on to keep water above 4F
- - Water temperature Current water temperature not measured