WARNING!
NEVER LIFT OR HANDLE WHIRLPOOL
BY SYSTEM PIPING AT ANY TIME.
LIFTING THE UNIT BY THE PIPING CAN
CAUSE SYSTEM DAMAGE.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
BODYWRAP SYSTEM
®
Bodywrap Whirlpool System
Assembly And Operation Guide
WARNING! Basic precautions should always be observed regarding the
installation and the operation of a whirlpool system, including
the following:
1.
2.
3.
4.
5.
6.
READ AND FOLLOW ALL INSTRUCTIONS.
DANGER: To reduce the risk of injury, DO NOT allow children to use
or operate the whirlpool unless closely supervised by an adult at all times.
Use this unit only for its intended purpose as described in this publication.
DO NOT use attachments not recommended by the manufacturer.
NEVER drop or insert any object into any opening.
To test the GFCI, push the test button. The GFCI should
interrupt power.
Push the reset button. Power should be restored.
DO NOT operate the whirlpool without the guard(s) (suction covers)
installed over the suction fitting(s).
The whirlpool system can only be connected to an electrical supply
that is protected by a ground-fault-circuit-interrupter (GFCI). The GFCI
should be provided by the installer and tested on a routine basis.
Bodywrap whirlpool systems are offered on
numerous MAAX models of various sizes,
shapes and surface materials. Depending
on the model selected, the unit is equipped
with a complete multi-jet factory installed
and tested system designed for personal
usage in a permanent installation. (Refer to
specific model for exact features.)
These guidelines are recommended by
MAAX Bath Inc. (hereafter “MAAX”) for
the proper assembly and operation of
the whirlpool system. A careful review of
these procedures (and any referenced
publications) before starting is important in
avoiding unnecessary problems resulting
in an improper assembly or operation.
It is the sole responsibility of the installer
to determine, prior to installation, the
requirements necessary for compliance
with all codes involving the unit and the
installation!
All paperwork packaged with the unit and
any associated options or accessories
should be saved and presented to the
homeowner upon completion of the
installation!
Any independent changes made to the
whirlpool system (or unit) beyond those
required for normal installation can void
all warranties! (Refer to warranties for
further information).
All published unit dimensions are for
reference only. Any critical dimensions
required for installation should be
taken directly from the unit being
installed!
NOTE: All drawings in this publication are
typical and may appear different than the
actual items.
Special Notes to Installer
>
>
>
>
If the GFCI fails to operate in this manner, there is a ground current
flowing, indicating the possibility of an electrical shock. DO NOT USE THE
WHIRLPOOL. DISCONNECT THE WHIRLPOOL SYSTEM, and have the
problem corrected by a qualified service representative before continuing
usage.
7.
A pressure wire connector is present on many pumps (pumps that have
some exposed metal on the housing) to permit connection of a No. 8 AWG
(8.4 mm2) solid copper bonding conductor between the system and all
other electrical equipment and exposed metal in the vicinity, as needed to
comply with local requirements. NOTE: pumps and other electrical
components that have all plastic housings do not have or require this
bonding conductor and do not have a pressure wire connector on the
housing.
-1-
10023064
Do not remove the Medallion Identification
Number. Doing so may affect the warranty.
This number may be found on the rim or
apron/skirt of the unit.
>
Question and Answer IconNeed help?

Do you have a question about the MAAX AKER and is the answer not in the manual?

MAAX AKER Specifications

General IconGeneral
BrandMAAX
ModelAKER
CategoryBathroom Fixtures
LanguageEnglish

Summary

Important Safety Instructions

General & Electrical Safety

Covers supervision, intended use, GFCI protection, grounding, and bonding conductor requirements.

Installer Notes & Warnings

Handling, Compliance & Warranty

Includes lifting warnings, code compliance, documentation, and modification impacts on warranty.

Inspection and Installation Guidelines

System Inspection Checks

Covers checks for air hose, in-line heater, and trim for basic and heater-equipped systems.

Installation Requirements

Details framing and dimensional requirements for whirlpool fittings, referencing packaging documents.

Pump Location Access Warning

Electrical Service and Connections

Wiring and GFCI Requirements

All wiring by licensed electrician; system must be connected to dedicated GFCI protected circuit.

Pump and Heater Wiring

Pump and optional heater require separate dedicated service lines and GFCI protection.

Whirlpool System Field Testing

Leak Testing Procedure

Steps to test for leaks after water, drain, and electrical connections are made, before enclosing.

Whirlpool System Operation

Pre-Operation Water Level

Ensure water level is at least to the top trim ring of the highest jet before starting.

Starting the System

Gently touch the button to start; a 20-minute timer cycle begins automatically.

Whirlpool System Care and Cleaning

Routine Cleaning Procedure

Use mild detergent and run system with dishwasher detergent, then rinse.

Sanitizing the System

Sanitize by substituting bleach for detergent during cleaning, followed by thorough rinsing.

Whirlpool System Troubleshooting

System Not Starting

Check GFCI, on/off button, pump connection, air hose, and wiring; consider thermal limiter.

Pump Hums, No Water Action

Check air controls, water level, jet blockage, suction line connection, and impeller.

Restricted Jet Flow

Verify air controls, jet flow settings, and pump-to-jet supply line for blockages.

Excessive Foaming

Clean and service the whirlpool system as per the care and cleaning section.

Operation Adjustments

Jet Directional Control

Move jet nozzle to direct flow as needed for side jets.

Air Control Adjustment

Turn air controls counter-clockwise to increase air/action, clockwise to reduce.

Jet Flow Adjustment

Rotate internal jet sections clockwise/counter-clockwise to adjust foot/side jet flow.

Overall System Flow Control

Use SELECTAFLOW™ knob to adjust overall system flow to High, Medium, or Low.

Limited Warranty

Warranty Coverage and Period

Warrants motor/pumps for 5 years, systems for 2 years, and ozonators for 1 year.

Warranty Limitations and Exclusions

Excludes damage from misuse, improper maintenance, alteration, or accidents; not liable for installation errors.

Commercial Use and Service

Commercial warranty is 1 year; service requires proof of purchase and authorized inspection.