EasyManua.ls Logo

Macurco OX-6 - User Manual

Macurco OX-6
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Macurco OX-6
Oxygen Detector, Controller and Transducer
User Instructions
Important: Keep these User Instructions for reference
Question and Answer IconNeed help?

Do you have a question about the Macurco OX-6 and is the answer not in the manual?

Summary

General Safety Information

Intended Use

Explains the purpose and application of the Macurco OX-6 Oxygen Detector.

Warnings and Cautions

Details critical safety warnings and precautions for using the detector.

Use Instructions and Limitations

Permitted Use Cases

Describes the intended applications and environments for the OX-6 detector.

Prohibited Use Cases

Specifies applications and conditions where the OX-6 should not be used.

General Description

Provides an overview of the OX-6's features and technology.

Features and Specifications

Key Features

Lists the key features and capabilities of the OX-6 detector.

Technical Specifications

Details the technical specifications of the OX-6, including power, size, and ratings.

Installation and Operating Instructions

Location and Mounting Guidelines

Guidance on where to mount the OX-6 unit for optimal performance.

Installation Steps

Step-by-step instructions for installing the OX-6 unit.

Wiring Diagrams

Small Garage Layout

Illustrates a common wiring diagram for a single garage installation.

Multiple Unit Layout

Shows wiring diagrams for installing multiple OX-6 units.

Control Panel Connections

Alarm Control Panel Connection

Diagram showing how to connect the OX-6 to an alarm control panel.

DVP-120 Control Panel Connection

Diagram showing connection to a specific control panel.

Operation Modes

Alternate Alarm Panel Connection

Shows an alternative wiring configuration for alarm control panels.

Power Up Sequence

Explains the unit's self-test cycle upon initial power activation.

Normal Operation Display

Describes how the OX-6 functions and displays readings during normal operation.

Factory Default Settings

Default Configuration Overview

Lists the default settings configured at the factory for the OX-6.

Configuration Menu Options

Default Configuration Selection

Instructions for changing the default configuration settings.

Power Up Test Configuration

Guide to configuring the power-up test feature.

Display and Buzzer Settings

Instructions for setting display and buzzer options.

Alarm Relay Configuration

Steps to select and configure alarm relay settings and mode.

Advanced Configuration Settings

Fan Relay Configuration

Guide to setting fan relay activation, delay, and runtime.

Trouble Fan and Latching Options

Instructions for configuring trouble fan and latching settings.

4-20 mA Output Configuration

Instructions for configuring the 4-20mA output feature.

Diagnostics and Error Handling

Onboard Diagnostics Overview

Information on the unit's internal diagnostics and error reporting.

4-20 mA Signal Troubleshooting

Explains how the 4-20mA signal indicates operational status or issues.

Error Code Reference

Lists and explains various error codes displayed by the OX-6.

Sensor Poisoning Information

Details substances that can degrade sensor performance.

Maintenance and Sensor Management

Periodic Maintenance Requirements

General overview of required periodic maintenance for the OX-6.

End-of-Warranty Signal

Explains the signal indicating the sensor's warranty expiration.

Sensor Replacement Procedure

Step-by-step guide for replacing the OX-6 sensor.

Sensor Life Reset Procedure

Instructions for resetting the sensor life after replacement.

Testing and Cleaning

Cleaning Instructions

Provides instructions on how to clean the exterior of the OX-6 unit.

General Testing Information

General introduction to testing procedures for the OX-6.

Detailed Operation Testing

Comprehensive Operation Test

Describes the procedure for performing a comprehensive operational test.

Manual Operation Test Options

Guide to manually initiating individual tests for relays and outputs.

Gas Testing Procedures

Oxygen Gas Test Overview

Details the procedure for testing the unit using oxygen gas.

Field Test Kit Information

Provides usage information for the Field Test Kit.

Relay Testing with Gas

Fan Relay Gas Test

Specific steps for testing the fan relay function with gas.

Output and Alarm Testing

Alarm Relay Gas Test

Procedure for testing the alarm relay functionality with gas.

4-20 mA Current Loop Gas Test

Steps to test the 4-20mA current loop output.

Field Calibration Procedure

Calibrating the Sensor to Clean Air

Detailed steps for calibrating the sensor in a clean air environment.

Product Warranty Information

Limited Warranty Terms

Details the warranty terms and conditions for the OX-6 detector.

Macurco OX-6 Specifications

General IconGeneral
Target GasOxygen (O2)
Sensor TypeElectrochemical
Response Time (T90)<30 seconds
Warranty2 years
Enclosure RatingIP65
Detection Range0-25%
Operating Temperature-20°C to +50°C
Output4-20mA
CertificationsUL, CSA
Operating Humidity15-90% RH non-condensing

Related product manuals