Provides an overview of the Macurco CX-xx detector's purpose and capabilities.
Key safety warnings and precautions for using the detector.
Details the intended applications and environments for the CX-xx detector.
Specifies environments and conditions where the CX-xx should not be operated.
Highlights the key functionalities and capabilities of the CX-xx detector.
Lists the technical details including size, weight, and electrical characteristics.
Specific technical details for the 6-Series low voltage model.
Specific technical details for the 12-Series line voltage model.
Guidelines for selecting the optimal placement of the detector for effective monitoring.
General steps and considerations for installing the CX-xx detector unit.
Specific installation procedures for the 6-Series low voltage model.
Specific installation procedures for the 12-Series line voltage model.
General information about connecting wires to the detector's modular connectors.
Detailed wiring instructions for the 6-Series low voltage model's terminals.
Detailed wiring instructions for the 12-Series line voltage model's terminals.
Describes the detector's behavior and self-test cycle upon initial power application.
Explains how the detector operates and displays information when the screen is active.
Details the detector's operational status and display behavior when the screen is inactive.
Information on the 4-20mA output signal for gas readings and trouble conditions.
Access and navigate the device's settings for customization and operation.
Lists the pre-programmed default operational settings of the CX-xx unit.
Procedure to reset the detector to its original factory default settings.
Option to enable or disable the power-up self-test sequence for the detector.
Allows selection between enabling or disabling the digital display.
Option to enable or disable the audible buzzer for alarms and alerts.
Configures the CO sensor's threshold for activating the alarm relay.
Configures the NO2 sensor's threshold for activating the alarm relay.
Sets the alarm relay to normally open (N.O.) or normally closed (N.C.) configuration.
Configures the CO sensor's threshold for activating the fan relay.
Configures the NO2 sensor's threshold for activating the fan relay.
Sets the time delay before the fan relay activates after a threshold is met.
Defines the minimum duration the fan relay remains active after activation.
Determines if the fan relay remains engaged until reset or disengages automatically.
Enables or disables the fan relay activation during a trouble condition.
Selects the output mode for the 4-20mA signal (Basic, Enhanced, Off).
Chooses between Dual or High mode for the 4-20mA output signal.
Sets the interval in months for CO sensor calibration reminders.
Sets the interval in months for NO2 sensor calibration reminders.
Monitors critical functions and indicates problems via error modes and alerts.
Identifies issues related to the 4-20mA output signal based on its current value.
List and explanation of error codes displayed by the detector for diagnostics.
Information on environmental contaminants that can deteriorate sensor performance.
Information on sensor lifespan, detection of expired sensors, and reset procedures.
Procedure to reset the sensor's operational life counter after replacement or calibration.
Guidelines for safely cleaning the external surfaces of the detector unit.
Checks the status indicator light and initiates a cycle test of the detector's functions.
Allows manual initiation of individual tests for relays, analog output, and gas response.
Information on necessary kits and procedures for calibrating the detector.
Procedures for testing the fan relay, alarm relay, and 4-20mA loop with calibration gas.
Procedure to verify the fan relay operation using calibration gas.
Procedure to verify the alarm relay operation using calibration gas.
Procedure to verify the 4-20mA output signal with calibration gas.
Quick functional test of the CO sensor using an aerosol gas.
Step-by-step instructions for performing zero and span calibrations.
Process to calibrate the CO sensor using clean air as a reference.
Process to calibrate the NO2 sensor using clean air as a reference.
Procedure to calibrate the CO sensor using a known concentration of test gas.
Procedure to calibrate the NO2 sensor using a known concentration of test gas.
Visual representation of the detector's main menu navigation and operational flow.
Diagram illustrating the sequence of automated tests available in the detector.
Visual guide to navigating and modifying the detector's operational settings.
Flowchart detailing the options and navigation within the detector's test menu.
Diagram showing the navigation path for performing sensor calibration procedures.
Flowchart illustrating the process for resetting sensor expiry information.