Installation instructions
Ultrasonic water meter
ElecTo Bulk
Important
Before installing the meter, please read this manual carefully.
This instruction sheet is for qualified technicians and does not contain the basic installation instructions.
The design and specifications of the meter may change and may not correspond to the description contained in these
instructions. In this event refer to the meter. These changes do not affect meter operation. For information contact the
manufacturer.
ElecTo Bulk is a precision instrument. Before leaving the factory it undergoes strict tests and is intended to be used by
qualified personnel.
If the meter fails to operate properly or requires repair, contact the manufacturer or an authorised dealer.
Do not shorten or lengthen the cable. This might affect meter performance.
The meters undergo strict tests before leaving the factory. Maintenance, replacement of components and calibration
must be carried out only by qualified personnel.
Contact the manufacturer for technical support.
In the event of loss of measuring data due to malfunction or other causes, the manufacturer commits to recover the
data. The manufacturer undertakes no responsibility if the loss of measuring data is caused by the user or by failure to
back up data.
The meter may be provided with a built-in pressure sensor for pipe pressure monitoring (optional).
Choice of the water meter
Before installing the meter ensure that the nominal diameter, nominal flow rate, working temperature and pressure are
compatible with the operating conditions.
Transport and storage
Water meters are precision instruments: handle with care and protect from shocks and vibration.
Store the meters in a frost-free place. Defrosting of the meter is a delicate operation.
Store the meters in a dry place, at a temperature between 0 °C and +50 °C. Do not expose to direct sunlight.
Recommendations for the installation
Before installing the meter check that the two pipe sections are aligned in order to avoid mechanical stress. Clean the
two pipe sections carefully (especially if the system is empty) and allow water to flow in the pipe for some time using a
pipe section instead of the meter.
If there is no water in the system, open the upstream valve before installing the meter. This is necessary to avoid
negative pressure from building when opening the valve at the end of the installation procedure because it might
damage the meter.
If the meter is installed in vertical or inclined position, the pipe must always be full of water.
Install the meter where it will be safe from frost (if necessary protect the meter with insulating material) and possibly in
the lowest part of the system to prevent air from building up.
Install the meter in a place where it will be protected from tampering and impact, and where it can be read easily.
Install the meter ensuring that the flow direction arrow on the body points in the same direction as the flow.
It is advisable to install a valve upstream and downstream of the meter in order to enable maintenance and verification
of the meter and monitoring of the system.
Operating conditions
Temperature class: T30/T50
Admissible pressure (MAP): 16 bar
Straight pipes and flow straighteners
For the usage of upstream and/or downstream straight pipes refer to the letters U and D marked on the dial. If the
letters U and/or D are followed by the letter S, a flow straightener must be installed.
Battery
The battery has a service life of 13 years. It is recommended to replace the battery before it is completely discharged in
order to avoid malfunction.

Other manuals for MADDALENA ElecTo Bulk

Question and Answer IconNeed help?

Do you have a question about the MADDALENA ElecTo Bulk and is the answer not in the manual?

MADDALENA ElecTo Bulk Specifications

General IconGeneral
BrandMADDALENA
ModelElecTo Bulk
CategoryMeasuring Instruments
LanguageEnglish

Summary

Installation Instructions

Important Pre-Installation Notes

Read manual carefully; design may change; contact manufacturer for support or repairs.

Water Meter Selection Criteria

Ensure nominal diameter, flow rate, temperature, and pressure compatibility with operating conditions.

Transport and Storage Guidelines

Handle with care, protect from shocks, store frost-free, dry, and out of direct sunlight.

Installation Recommendations

Align pipes, clean sections, manage upstream valve, ensure full pipe, protect from frost/tampering.

Operating Conditions

Temperature class T30/T50 and admissible pressure (MAP) of 16 bar.

Pipe Straightener Requirements

Use upstream/downstream straight pipes as marked (U, D) and install straighteners if S is indicated.

Battery Information

Battery has a 13-year service life; replace before complete discharge to avoid malfunction.

Installation Procedure

Step-by-Step Installation

Connect meter to pipe, position flange, tighten bolts ensuring gasket alignment and leak prevention.

Liquid Crystal Display (LCD) Navigation

Meter has primary and secondary menus; navigate using magnetically operated button.

Display Menus and Data

Primary Menu Displays

Shows volume flowed, pipe pressure, and single screen view options for flow rate.

Secondary Menu Data

Provides details like date, time, operating times, firmware versions, and calibration parameters.

Meter Seals and Servicing

Meter is sealed; must be serviced by an authorized center; altering seal voids warranty.

Hazardous Substances and Compliance

Substance Content Information

Details on toxic/hazardous substances, indicating concentrations relative to SJ/T11363-2006.

Waste Electrical and Electronic Equipment (WEEE)

Manufacturer/dealer must take back WEEE; water meter must not be disposed of with household waste.

Declaration of Conformity

Ultrasonic water meter ElecTo Bulk complies with Directive 2014/32/EU and ISO 4064.

Manufacturer Contact and Warranty

Contact details for Maddalena S.p.A. and information on sales and warranty terms.

Related product manuals