Installation and Operating Instructions
Compact Thermal Energy Meter (Heat Meter, Combined Heat/Cooling Energy Meter)
microCLIMA U/SENSOSTAR®2U
DE-13-MI004-PTB001 (MID heat)
1 Application and Function
Thermal energy meter (heat meter or combined heat/cooling meter) designed for the measurement of the
consumed thermal energy in a closed heating or heating/cooling system.
2 Contents of the Package
- Thermal energy meter (heat meter or combined heat/cooling meter) consisting of a detachable calculator,
a flow sensor and two temperature sensors, all permanently connected to each other.
- Installation kit
- Installation and Operating Instructions
3 General Information
- Valid standards for the application of heat meters: EN 1434, parts 1 6; the Measuring Instrument
Directive 2004/22/EC, Annexes I and MI-004; and the relevant national verification regulations.
- For the selection, installation, commissioning, monitoring and maintenance of the instrument observe the
standard EN 1434 part 6 as well as Annex 22 of the verification regulations (for Germany).
- National regulations for the consumption measurement of cooling must be observed.
- The technical regulations for electrical installations must be observed.
- This product fulfils the requirements of the European Council Directive on Electromagnetic Compatibility
(EMC Directive) 2004/108/EC.
- The identification plate of the instrument and the seals must not be removed or damaged otherwise the
guarantee and the approved application of the instrument are no longer valid!
- To achieve measurement stability of the meter is it necessary that the water quality meet the requirements
of the AGFW-recommendation FW-510 and the document VDI (Association of German Engineers) VDI 2035.
- The heat meter left the factory in conformance with all applicable safety regulations. All maintenance and
repair work is to be carried out only by qualified and authorized technical personnel.
- The instrument must be stored and transported at temperatures above-freezing.
- Instruments with activated radio function are not allowed on air freight.
- The correct installation point in the system must be chosen: forward or return flow, as stated on the type
identification label.
- The temperature sensor cables and the cable between the calculator and flow sensor must not be kinked,
rolled up, lengthened or shortened.
- To clean the heat meter (only if necessary) use a slightly moist cloth.
- To protect against damage and dirt the heat meter should only be removed from the packaging directly
before installation.
- If more than one heat meter is installed in one unit, care must be taken to ensure that all the meters have
the same installation conditions.
- All specifications and instructions listed on the data sheet and in the Application Notes must be adhered to.
- Further information can be obtained at www.engelmann.de.
- Instruments which have been replaced or exchanged must be disposed of according to relevant
environmental regulations.
- The display is deactivated and can be activate for one minute by pushing the button (except calculator
without additional interfaces).
Question and Answer IconNeed help?

Do you have a question about the MADDALENA microCLIMA U and is the answer not in the manual?

MADDALENA microCLIMA U Specifications

General IconGeneral
BrandMADDALENA
ModelmicroCLIMA U
CategoryMeasuring Instruments
LanguageEnglish

Summary

1 Application and Function

2 Contents of the Package

3 General Information

3.1 Definition of Pictograms

4 Mounting the Flow Sensor

5 Mounting the Temperature Sensors

5.1 Direct Mounting

Instructions for directly mounting temperature sensors using ball valves or T-pieces.

6 Start of Operation

7 Display

8 Technical Data

Approval Data

Presents approval data, accuracy classes, and sensor specifications for the meter.

Flow Sensor Technical Data

Details technical specifications related to the flow sensor, including nominal diameter and pressure drop.

8.1 Calculator Technical Data

8.2 Temperature Sensors Technical Data

9 Additional Interfaces

9.1 Optical Interface

Information on the infrared optical interface for data communication.

9.2 M-Bus Interface

Details the optional M-Bus interface for meter data transmission.

9.3 M-Bus Interface Information

9.3.1 M-Bus Norms and Standards

9.3.2 M-Bus Technical Specifications

9.3.3 M-Bus Technical Data

9.3.4 M-Bus Read-out Limits

9.4 Radio Interface

General Information on Radio Interface

Provides general information regarding the wireless M-Bus radio interface.

9.4.1 Radio Technical Data

Specifies technical data for the radio interface, including frequency and telegram types.

9.4.2 Radio Configuration

Details the configuration parameters and factory settings for the radio interface.

9.4.3 Radio Interface Activation

9.5 Pulse Inputs

General Information on Pulse Inputs

Provides general information regarding the optional pulse inputs for external meters.

9.5.1 Pulse Input Norms

Lists relevant norms, standards, and literature for pulse inputs.

9.5.2 Pulse Input Technical Data

Details the technical data for pulse inputs, including voltage and resistance.

9.5.3 Pulse Output Electrical Requirements

9.5.4 Setting Up Pulse Inputs

9.5.5 Pulse Input Set-up Possibilities

9.5.6 6-Wire Cable Pin Assignments

9.5.7 4-Wire Cable Pin Assignments

9.6 Potential-Free Pulse Output

9.6.1 Pulse Output Technical Data

10 Information Messages

10.1 Message Description

Details the effect and possible causes of various information messages displayed by the meter.

11 Mounting with Wall Support

12 MID Declaration of Conformity

13 Manufacturer

14 Contact

Related product manuals