EasyManua.ls Logo

Made GasTracker - Procedure for Connection of the Transmitter

Made GasTracker
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GU_GAS_TRACKER_V_1_00_US 6/18
Procedure for connection of the transmitter
1. Connecting the resonator tank.
- Disconnect a customer’s meter with all the safety procedures required for this operation.
(Or find an access point anywhere on the network).
- Affix the resonator tank to the pipe end thanks to the proper adaptor.
- Check to ensure the purge valve is open (on the resonator tank).
- Slowly open the gas valve and check there are no leaks on the pipe.
- Using the purge valve of the resonator tank, remove the air out of it totally.
(Keep the purge valve open about 5 seconds)
- Close the purge valve on the resonator tank.
- Open your gas valve fully.
Now your system is safely connected to the gas network, and almost ready to be used.
2. Connecting the transmitter and starting it.
- Plug the orange cord from the transmitter to the resonator tank.
- Press the ‘on’ button.
You should now hear the noise of the signal.
ATTENTION: ALWAYS OPEN/CLOSE NETWORK AND PURGE VALVE SLOWYLY TO AVOID
DAMAGING THE MEMBRANE INSIDE THE RESONATOR TANK.
Repeated shocks due to pressure on the membrane may break it.