GU_GAS_TRACKER_V_1_00_US 6/18
Procedure for connection of the transmitter
1. Connecting the resonator tank.
- Disconnect a customer’s meter with all the safety procedures required for this operation.
(Or find an access point anywhere on the network).
- Affix the resonator tank to the pipe end thanks to the proper adaptor.
- Check to ensure the purge valve is open (on the resonator tank).
- Slowly open the gas valve and check there are no leaks on the pipe.
- Using the purge valve of the resonator tank, remove the air out of it totally.
(Keep the purge valve open about 5 seconds)
- Close the purge valve on the resonator tank.
- Open your gas valve fully.
Now your system is safely connected to the gas network, and almost ready to be used.
2. Connecting the transmitter and starting it.
- Plug the orange cord from the transmitter to the resonator tank.
- Press the ‘on’ button.
You should now hear the noise of the signal.
ATTENTION: ALWAYS OPEN/CLOSE NETWORK AND PURGE VALVE SLOWYLY TO AVOID
DAMAGING THE MEMBRANE INSIDE THE RESONATOR TANK.
Repeated shocks due to pressure on the membrane may break it.