OPERATION
INSTRUMENT PANEL
60 Operating Manual MT 25 / 30 YT
Bypassing safety switch-off of the motor
If the motor coolant temperature or the motor oil pressure
exceed the specified limit values, this is indicated by a flashing
LED in the multi-function display (warning threshold 1). Should
the limit values be further exceeded an acoustic signal sounds
(warning threshold 2). 30 seconds after the acoustic warning
signal the motor switches off automatically. When the acoustic
signal is given the control light “Bypassing the safety switch-
off” lights up.
CAUTION!
Material damages!
Bypassing the safety switch-off can lead to serious
damage of the motor.
X Only bypass the safety switch in a case
of emergency.
The safety switch-off can be bypassed when leaving a danger
zone.
Fig. 44: Button with control light “Bypassing the safety switch-off”
X
Press the switch down.
3 The safety switch-off is bypassed.
The safety switch-off can be bypassed within the
30 seconds after the acoustic warning signal is given.