Flex VUE™ Transmitter Instruction Manual
July 2013
Page 33 of 41
To send a program file to a Flex VUE™ Transmitter
1. Plug in the USB programming cable.
2. Click the “send” button on the RCP screen. A dialog box will pop up confirming that you want to
proceed. Check the box marked “I accept,” and then click the button “Continue send to radio.”
On-screen prompts will confirm that the receiver has been programmed or if there are any issues.
3. Data will need to be sent separately for the Unit Info and CAN Configuration screens.
Receiving (Reading) the Flex VUE™ Programming
To read a program file from the Flex VUE™ Transmitter
1. Plug in the USB programming cable.
2. Click “Receive” and follow onscreen prompts.
3. RCP will confirm reception and automatically display current programming in the Flex VUE™ unit.
Reading the RCP Software Version
1. Select “Help”.
2. Select “About”.
3. The RCP Software Version number will be displayed.
Resetting Flex VUE™ Back to Factory Default Settings
1. Select “Reset to Defaults” button.
2. A dialog box will pop up confirming that you want to proceed. Click the button “OK” to restore the
factory default settings. On-screen prompts will confirm that the transmitter has been reset to
defaults or if there are any issues.
3. Power cycle the Flex VUE™ transmitter to implement the factory default values.
NOTE: Resetting the system back to factory defaults only restores the factory settings for the CAN
configuration settings. All other settings will not be altered.