EasyManua.ls Logo

Majestic 36LDVR - User Manual

Majestic 36LDVR
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation Instructions and
Homeowners Manual
10007317 1/13 Rev. 17
Builder Rear Vent Direct Vent
Models: 33LDVR, 36LDVR,
39LDVR, 43LDVR
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from your neighbor’s phone. Follow
the gas suppliers instructions.
If you cannot reach your gas
supplier call the re department.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
INSTALLER/CONSUMER
SAFETY INFORMATION
FOR YOUR SAFETY
Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
-
Ê
,
/
Ê
7317
LDVR COVER
1/05
 ,/  
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Table of Contents

Questions and Answers

  • J
    Johnathan DayAug 16, 2025
    Why does my Majestic 36LDVR Indoor Fireplace pilot light keep going out?
    • M
      Michelle DudleyAug 16, 2025
      Frequent pilot outages in your Majestic Indoor Fireplace can be caused by: * **Pilot flame issues:** The pilot flame might be too low or too high, causing the pilot safety to shut off the gas supply. In this case, you should clean and adjust the pilot flame for maximum flame impingement on the thermopile and thermocouple. * **Vent terminal blockage:** Check the vent terminal for any obstructions that might be recycling the flue gases.
  • D
    donna05Aug 23, 2025
    What to do if the pilot will not stay lit on my Majestic 36LDVR Indoor Fireplace?
    • J
      Joy LuceroAug 23, 2025
      If the pilot light won't stay lit on your Majestic Indoor Fireplace after following the lighting instructions, consider these potential causes: * **Defective pilot generator (thermocouple) or remote wall switch:** Check the pilot flame to ensure it properly impinges on the thermocouple/thermopile. Clean and/or adjust the pilot for maximum flame impingement on the thermopile and thermocouple. * **Defective automatic valve:** Turn the valve knob to the “Pilot” position. While maintaining gas flow to the pilot, a millivolt meter should read greater than 10 mV. If the reading is okay but the pilot still doesn't stay lit, the gas valve needs to be replaced. Note: An interrupter block (not supplied) must be used to conduct this test.
  • J
    Justin OlsonAug 31, 2025
    How to fix a spark ignitor that will not light on a Majestic 36LDVR?
    • R
      Robert RichardsAug 31, 2025
      If the spark ignitor on your Majestic Indoor Fireplace isn't lighting, here's what to check: * **Defective or misaligned electrode:** First, try lighting the pilot with a match. If it lights, turn off the pilot and try the ignitor button again. If the pilot still won't light, check the gap at the electrode and pilot. It should be 1/8” to ensure a strong spark. * **Defective ignitor (push button):** Push the Piezo Ignitor Button and check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the ignitor.
  • Q
    qwilsonNov 7, 2025
    What to do if the pilot is burning, but no gas to the main burner in my Majestic 36LDVR?
    • S
      Stanley KempNov 8, 2025
      If the pilot light is on but the main burner isn't receiving gas, there are several potential causes: * **Wall switch or wiring issues:** Inspect the wall switch and wiring for secure connections. You can test the switch by using a jumper wire across the terminals. If the burner ignites, the wall switch is faulty and needs replacement. If the switch is fine, try using a jumper wire across the wall switch wires at the valve. If the burner then comes on, the wires are faulty or the connections are bad. * **Insufficient millivoltage from the thermopile:** Ensure that the wire connections from the thermopile to the gas valve terminals are secure and that the thermopile is fully inserted into the pilot bracket. Check for a ground in one of the wall switch wires. If the pilot stays lit afte...

Summary

Installer;Consumer Safety Information

General Safety Precautions

Safety instructions for installation, service, and general use.

Gas Leak Emergency Procedures

Actions to take if gas is detected, including warnings and contact procedures.

Flammable Material Warning

Prohibition of storing flammable liquids near the appliance.

Installation & Operating Instructions

General Installation Requirements

General safety, cautions, codes, and operating requirements.

Fireplace Dimensions & Location

Physical dimensions, framing, and location selection guidelines.

Clearances, Mantels & Hearth

Safe distances from combustibles, and mantel/hearth installation.

Finishing & Gas Specifications

Instructions for finishing, gas types, pressures, and air shutter adjustment.

Gas Line & Electrical Installation

Procedures for installing gas lines and electrical connections, including switches.

Venting System Basics

General guidelines for venting, termination location, and pipe assembly.

Vent Termination Clearances & Locations

Specific clearances and locations for vent termination based on codes.

Vent Pipe Assembly & Clearances

General procedures for assembling vent pipes and their clearances.

Vent Pipe Types & Installation Methods

Information on twist lock pipes, flex pipes, rear wall, and sidewall venting.

Vertical Sidewall & Through-Roof Installation

Detailed steps for vertical sidewall and through-roof venting.

Below Grade Installation

Procedures for installing the fireplace below grade level.

Venting Components

Approved Venting Components List

List and descriptions of approved venting components for the fireplace.

Glass Handling, Removal & Cleaning

Log, Lava Rock & Ember Installation

Log Identification & Placement

Identifies logs and provides general installation steps and model-specific placement.

Flame Adjustment & Characteristics

Lighting & Operating Instructions (SIT820 Valve)

Pre-Lighting Safety & Gas Checks

Critical safety warnings and procedures for detecting gas leaks.

SIT820 Valve Lighting Procedure

Step-by-step guide to safely light the fireplace pilot and burner.

Shutting Off Gas

Procedure to safely shut off gas supply to the appliance.

Lighting & Operating Instructions (SIT822 Valve)

Pre-Lighting Safety & Gas Checks

Safety warnings and gas leak detection for SIT822 valve.

SIT822 Valve Lighting Procedure

Step-by-step lighting procedure for SIT822 valve.

Shutting Off Gas

Procedure to safely turn off gas for SIT822 valve equipped appliances.

Lighting & Operating Instructions (AF4000 Valve)

Pre-Lighting Safety & Gas Checks

Safety warnings and gas leak detection for AF4000 valve.

AF4000 Valve Lighting Procedure

Step-by-step lighting procedure for AF4000 valve.

Shutting Off Gas

Procedure to safely turn off gas for AF4000 valve equipped appliances.

Gas Control System Troubleshooting

SIT NOVA 820 Millivolt Valve Issues

Troubleshooting guide for the SIT NOVA 820 Millivolt gas control valve.

SIT 822 Valve Troubleshooting Flowchart

Troubleshooting flow chart for SIT 822 valve with Synetek control.

American Flame System Troubleshooting

Troubleshooting guide for the American Flame gas control system.

American Flame Error Codes

Explains error codes for the American Flame gas control system.

Fuel Conversion Instructions

Valve Conversion Procedures

Procedures for converting SIT 820 NOVA and AF4000 gas control valves.

Maintenance

Burner, Fan & Pilot System Maintenance

Guidance on cleaning and maintaining burner, fan, and pilot systems.

Parts List

Exploded View & Component Lists

Exploded view diagram and detailed lists of replacement parts.

Fuel Conversion Kit Numbers

Part numbers for natural gas to propane conversion kits.

Optional Accessories

Fan Kits & Wiring

Information and specifications for optional fan kits and wiring.

Ceramic Panels & Remote Controls

Installation of ceramic panels and overview of remote control units.

Trim, Screen Door & Face Kits

Available optional trim, screen door, and face kits for models.

LIMITED LIFETIME WARRANTY

Warranty Coverage Details

Details of lifetime, five-year, and basic warranty coverage.

EnerGuide Efficiency Ratings

Model Efficiency Ratings

Energy efficiency ratings for various models based on EnerGuide standards.

Majestic 36LDVR Specifications

General IconGeneral
VentingDirect Vent
Log MaterialCeramic Fiber
Fuel TypeNatural Gas or Liquid Propane
Efficiency70%
Ignition TypeElectronic

Related product manuals