Installation Instructions and
Homeowners Manual
C E RT I F I E D
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
10007852 1/13 Rev. 17
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from your neighbor’s phone. Follow
the gas suppliers instructions.
If you cannot reach your gas
supplier call the re department.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
INSTALLER/CONSUMER
SAFETY INFORMATION
FOR YOUR SAFETY
Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
Builder Top Vent
Direct Vent
Models: 33LDVT, 36LDVT
39LDVT, 43LDVT

,$64COVER

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Table of Contents

Questions and Answers

  • E
    Edward CoxAug 10, 2025
    What to do if my Majestic 33LDVT has a frequent pilot outage problem?
    • S
      Stephanie LopezAug 10, 2025
      If the pilot light on your Majestic Indoor Fireplace frequently goes out, it could be due to a pilot flame that is either too low or too high, causing the pilot safety to shut off. To resolve this, clean and adjust the pilot flame to ensure maximum flame impingement on the thermopile and thermocouple. Another possible cause is a blockage in the vent terminal. Inspect the vent terminal for any obstructions that might be recycling flue gases.
  • H
    hoffmanlawrenceAug 20, 2025
    What to do if the pilot will not stay lit on my Majestic Indoor Fireplace?
    • M
      Michael ThompsonAug 20, 2025
      If the pilot light on your Majestic Indoor Fireplace won't stay lit after following the lighting instructions, there are a couple of potential reasons. First, the pilot flame might not be properly impinging on the thermocouple/thermopile. Make sure to clean and adjust the pilot to maximize flame impingement. Second, the automatic valve could be defective. To check this, turn the valve knob to 'Pilot' and maintain flow to the pilot; a millivolt meter should read greater than 10 mV. If the reading is okay but the pilot still doesn't stay on, the gas valve may need to be replaced.
  • L
    Leah ReeseAug 26, 2025
    How to fix a spark ignitor that will not light on a Majestic 33LDVT Indoor Fireplace?
    • D
      Dakota LewisAug 26, 2025
      If the spark ignitor on your Majestic Indoor Fireplace isn't lighting, it could be due to a defective or misaligned electrode at the pilot. Try lighting the pilot with a match. If it lights, turn it off and push the red button again. If it still doesn't light, check the gap at the electrode and pilot, ensuring it's about 1/8 inch for a strong spark. Alternatively, the ignitor itself (push button) might be defective. Check for a spark at the electrode and pilot when pushing the Piezo Ignitor Button. If there's no spark and the electrode wire is properly connected, you may need to replace the ignitor.
  • K
    Kevin RossSep 4, 2025
    Why does the pilot light keep going out on my Majestic Indoor Fireplace?
    • F
      fwadeSep 4, 2025
      A frequent pilot outage in your Majestic Indoor Fireplace could be due to a pilot flame that's either too low or too high, causing the pilot safety to drop out. To resolve this, clean and adjust the pilot flame to ensure maximum impingement on both the thermopile and thermocouple. Another possible reason is a blockage in the vent terminal, which can recycle flue gases. Inspect the vent terminal for any obstructions.
  • S
    Samuel CookNov 14, 2025
    Why is my Majestic 33LDVT pilot burning, but no gas goes to the main burner?
    • E
      esampsonNov 14, 2025
      If your Majestic Indoor Fireplace pilot is burning but no gas is reaching the main burner, the issue could stem from several causes. First, inspect the wall switch and its wiring for proper connections; if a jumper wire across the terminals makes the burner ignite, replace the defective wall switch. Second, ensure that the wire connections from the thermopile to the gas valve terminals are secure and that the thermopile is fully inserted into the pilot bracket; a millivolt meter should read 250-300 millivolts (minimum 150) at the thermopile terminals of the gas valve. Third, check the burner orifices for any obstructions and clear them. Finally, with the valve knob and wall switch set to 'On', a millivolt meter should read greater than 100 mV; if the reading is adequate but the burner stil...
  • B
    Benjamin YoungDec 1, 2025
    What to do if the Majestic Indoor Fireplace pilot is burning, but there's no gas to the main burner?
    • M
      Marissa PalmerDec 1, 2025
      If the pilot light is on but the main burner isn't receiving gas, several issues could be the cause. First, check the wall switch and wiring for secure connections. You can bypass the wall switch by using a jumper wire across the terminals; if the burner ignites, the switch is likely defective and needs replacement. If that doesn't work, try jumping the wires at the valve; if the burner then comes on, the wires are faulty or poorly connected. Also, the thermopile might not be generating enough millivoltage. Ensure the wire connections from the thermopile to the gas valve terminals are tight and that the thermopile is fully inserted into the pilot bracket. One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals; if pilot now stays lit, trace wall switch w...

Majestic 33LDVT Specifications

General IconGeneral
Log MaterialCeramic Fiber
Fuel TypeNatural Gas or Liquid Propane
VentingVenting Required
Vent TypeDirect Vent
EfficiencyUp to 70%