Input Impedance 10M (VDC and VAC)
AC response True rms (AAC and VAC)
ACV Bandwidth 2KHZ
Operating Temperature 5
o
C to 40
o
C (41
o
F to 104
o
F)
Storage Temperature -20
o
C to 60
o
C (-4
o
F to 140
o
F)
Operating Humidity Max 80% up to 31
o
C (87
o
F)
Decreasing linearly to 50% at 40
o
C
(104
o
F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft.) maximum.
Battery 2 x 1.5V AAA Battery
Battery life Approx. 30h (backlight ON), Approx.
100h (backlight OFF)
Auto power OFF After approx. 15 minutes
Dimensions 123 (W) x 270 (D) x 39 (H)mm
Weight 280g
Safety For indoor use and in the requirement
For double insulation IEC1010-1(2001):
EN61010-2-030, EN61010-2-032,
EN61010-2-033 Overvoltage Category
III 600V, Pollution Degree 2.