Exhaust gas turbocharger - HPR 5000 -
Repair / Replacement
A5.05. 06.13.02.11
12000, 24000, 48000, 250, 1000
M20
en / 31.05.2010 IB025473 1/2
06
See also: A3.06.06.nn
Spare parts list: B1.05.06.nn725n nn
Time requirement: 1 Pers./ 0,40 h
Personnel qualification: skilled engine hand
--------------------------------------------------------------------------------------------------------------------------------
Operating medium: Heavy fuel
NOTE
The exhaust gas turbocharger must generally be maintained according to the main-
tenance instructions in Book C or the Operating Instructions.
Below is a list of maintenance tasks that must be performed using the work interval
schedule according to the operating instructions in Book C after the number of oper-
ating hours listed.
The operating hours listed are guidelines that may need to be shortened or length-
ened depending on the operating conditions, as well as for adapting to engine main-
tenance intervals.
For "Washing the Turbocharger", the work processes are described in work cards
(A5.05.06.05.01.nn) & (A5.05.06.05.02.nn) .
Instructions for emergency engine operation with a defective turbocharger see User
Manual A3.12.01.nn.