Emergency Stop
Safety System
A0.04
M20/M25/M32/M43
en / 15.12.2010 AA033984 3/5
2.3 Emergency stop due to high lube oil temperature
Checks:
Check temperature sensor.
Check oil cooler.
Check cooling water circuit.
Pressurize each cylinder through opened indexing valves with shop air.
If there is a rapid pressure drop or if no pressure builds up the cause must be investigated.
2.4 Contact the Caterpillar/ MaK Service.
3. Engine room monitoring
Emergency Stop due to excessive oil mist concentrationsee engine documentation, chap-
ter "Operating Instructions".
Checks:
Check engine room monitoring device (operational test),
see "engine documentation, chapter "External Documentation" C5.05.11.02.03. nn.
Visual inspection of engine and gear train,
of cam shaft trough,
of combustion chamber,
of turbo charger.
3.1 Contact your Caterpillar Service.
4. Cooling water (fresh water - HT, pressure and temperature)
Emergency stop due to excessively high cooling water temperature
Checks:
Visual inspection of engine
Check temperature sensors
Check fresh water cooler
Operational test of LT - Cooling water circuit with cooling water pump.
4.1 Contact your Cater
pillar Service.