9
I-4 Specifications
I-4-1 Memory unit
Item Specification
Model Name RCX-S
Measuring Temp. Range 0500 *
Max Measuring Time Approx. 10 hours * *
Sampling Time (sec.)
/Max. Storage Time
0.05sec./4h50min, 0.1sec./10h40min,
0.2sec./21h20m+in, 0.5sec./48h20min,
1.0sec/96h40min, 2.0sec./193h20min,
4.0sec/386h40min, 8.0sec./773h20min
Arbitrary setup possible
Temperature Accuracy ±1 * 3
Measuning Points 1-6 Points
Heat Resistant
Connector
Miniature Connector
Input
Thermocouple JIS-K 1k max.
0.1 10m
Power Supply
AAA battery
Manganese batteries
Alkaline battery
Nickel-metal hydride
Lithium Ion Battery (option)
Outer dimensions
Memory unit (w/o Heat resistant case) 50 (W) x 170 (D) x 18 (H) mm
Heat resistant case: 65 (W) x 245 (D) x 25 (H) mm
Data Transmission
Method
USB , Bluetooth
Weight Approx. 550g (Conveyor Attachment System are not included)
* 1 It differes from the heat resistant time of memory unit.
* 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.
* 3 The errors of thermocouple and reference junction temperature are not included in the temperature
accuracy.