6.4 Commissioning
Operate new and overhauled engines at no greater than around 3/4 load during the initial hours of opera
tion; however operate at varying engine speeds.
After this time period the engine can be slowly brought up to full power.
IMPORTANT!
Termination of liability for material defects by use of non-approved fluids and lubric
ants!
Liability for material defects is terminated if non-approved fluids and lubricants are used.
For this reason:
S Only use approved fluids and lubricants (see “Fluids and Lubricants ..." publication).
6.4.1 Filling Diesel Fuel
DANGER!
Risk of fire caused by diesel fuel!
Diesel fuel is highly flammable.
For this reason:
S No smoking and no open fires when handling fuels.
S Only refuel with engine off.
S Ensure cleanliness.
S Do not let fuel drip or leak out.
IMPORTANT!
Component damage to injection system caused by water in diesel fuel!
Absolutely prevent any ingress of water.
For this reason:
S Install a prefilter and a water separator into the fuel supply.
1. Fill diesel fuel according to the instructions of the manufacturer of the complete system.
2. Open fuel shutoff valve.

Table of Contents