3-24
D6 - Hydraulic oil
DRAIN  REPLACE
- Set the platform on a horizontal surface in transport position, with the engine switched off.
- Raise the work platform approximately 3m.
- Turn the maintenance and then lower the scissors assembly by pressing on the arm.
- Close the hydraulic circuit shut off valves if the platform is equipped with these.
Use a very clean container and funnel and clean the top of the oil can before
filling
.
Dispose of the drained oil in an environmentally friendly manner.
The engine should not start if the automatic shut off valves on the hydraulic
reservoir are in the closed position: there is a risk of damage to the components.
If the reservoir valves are shut, remove the machine’s ignition key and stick a label on the platform to inform personnel of
its condition.
- Remove the drain cap from the hydraulic reservoir and drain the reservoir completely into an appropriate container.
A fine spray of hydraulic oil can penetrate and burn the skin. Loosen hydraulic connections very slowly to enable the
h
ydraulic pressure to dissipate gradually.
D6
ClosedOpen
647367 (01/03/2017)
100/120 SC-2 / 140 SC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitou 100 SC-2 and is the answer not in the manual?

Manitou 100 SC-2 Specifications

General IconGeneral
BrandManitou
Model100 SC-2
CategoryLifting Systems
LanguageEnglish

Related product manuals