13
Installation of the AR-10000,
AR-20000 and AR-40000 Filter Systems
– Remove protective cap
from cartridge
– Inspect cartridge and o-
rings for damage
– Lubricate o-rings with food
grade lubricant
– Insert cartridge into head
assembly
– Rotate 1/4 turn to the right
to secure
– Product label will be facing
front
NOTE: Flush cartridge for 2 minutes to
remove trapped air and carbon fines.
AR-Pre, AR-10000 and AR-20000
AR-40000
• Installation of filter cartridges
Installation of AR-Pre
Use the following procedure
to install the AR-Pre when
your AR-10000, AR-20000
or AR-40000 filter system
has been installed.
– Shut off the incoming
water supply.