26 Part Number 000015433_05 3/21
Detailed Descaling and Sanitizing Procedure
Use Ice Machine Cleaner/Descaler part number
000000084.
Use Ice Machine Sanitizer part number 9405653.
Step 1 Remove front and top covers and set the toggle
switch to the OFF position.
Step 2 Remove all ice from the bin.
Step 3 Turn off the ice making water supply and drain
water from evaporator and reservoir.
Step 4 Remove the top cover from water reservoir.
Step 5 Follow the chart and premix cleaner and water.
Amount of Water Amount of Cleaner/Descaler
Part Number 000000084
1 gallon (4 Liters) 3 ounces (90 ml)
Step 6 Fill the evaporator and reservoir with descaling
solution.
Important
Prop Float Up to Prevent Low Water Level Shutdown