84 Part Number 000015433_05 3/21
HIGH PRESSURE CUTOUT (HPCO) CONTROL
Model Cut-Out Cut-In
RNF0320 / RFF0620
RFF1300 / RNF0320
RNF0620 / RNF1100
325 psig ±10
(2250 kPa ±69)
22.5 bar ±.69
200 psig ±10
(1379 kPa ±69)
13.79 bar ±.69
Auto Reset
RFF2500
435 psig ±10
(3000 kPa ±69)
30 bar ±.69
Manual Reset
RNF1020C / RCUF1000
RFF1220C / RCUF1200
RNF2000C / RCUF2200
RFF2200C / RCUF2200
450 psig ±10
(3100 kPa ±69)
31 bar ±.69
300 psig ±10
(2068 kPa ±69)
20 bar ±20.68
Auto Reset