104 Part Number 80-01111-9 7/10
INSTALLATION AND VISUAL INSPECTION
CHECKLIST
Ice machine is not level
Level the ice machine
Condenser is dirty
Clean the condenser
Water filtration is plugged (if used)
Install a new water filter
Water drains are not run separately and/or are not
vented
Run and vent drains according to the Installation
Manual