EasyManuals Logo
Home>Manitowoc>Ice Maker>SMS050A

Manitowoc SMS050A Technician's Handbook

Manitowoc SMS050A
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Part Number 80-01111-9 7/10 27
Electrical Requirements
VOLTAGE
The maximum allowable voltage variation is ±10% of
the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
The 115/1/60 ice machines are factory pre-wired with
a 6' (1.8 m) power cord, and NEMA 5-15P-plug
configuration.
The 208-230/1/60 and 230/1/50 ice machines are
factory pre-wired with a power cord only, no plug is
supplied.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
TOTAL CIRCUIT AMPACITY
The total circuit ampacity is used to help select the
wire size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must
be determined by a qualified electrician.

Table of Contents

Other manuals for Manitowoc SMS050A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SMS050A and is the answer not in the manual?

Manitowoc SMS050A Specifications

General IconGeneral
BrandManitowoc
ModelSMS050A
CategoryIce Maker
LanguageEnglish

Related product manuals