Part Number STH042 7/15 77
Safety Limit 3
Freeze time reaches 4 minutes and water is not
sensed.
Possible Cause Checklist
Improper installation
Refer to “Installation/Visual Inspection Checklist” on
page 67
Water System
Dirty/defective water dump valve
Low water float valve dirty or defective
Vent tube not installed on water outlet drain
Low water pressure (20 psig min.)
Dirty defective water filter (when used)
Loss of water from sump area
Dirty/defective water inlet valve
Electrical system
Water inlet valve coil defective
Low water float valve defective