EasyManuals Logo

Manitowoc UG030A Technician's Handbook

Manitowoc UG030A
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
43
Check Procedure
1. Make sure the thermistor sensors installation
correctly
2. Disconnect thermistor from control board and
measure resistance.
3. Measure temperature at the thermistor.
4. Compare measured resistance/
temperature.Creadings to resistance/temperature
relationship
Within 10% of the published resistance value-
Thermistor is good
Not within 10% of the published resistancevalue -
Thermistor is defective.

Table of Contents

Other manuals for Manitowoc UG030A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc UG030A and is the answer not in the manual?

Manitowoc UG030A Specifications

General IconGeneral
BrandManitowoc
ModelUG030A
CategoryIce Maker
LanguageEnglish

Related product manuals