Caution
Read this instruction before operating this equipment.
Part Number: 040006977 09/22

Questions and Answers

  • T
    Timothy RiveraAug 9, 2025
    Why is my Manitowoc Sotto UG-40 running but not making ice?
    • R
      Rebecca RaymondAug 10, 2025
      If your Manitowoc Ice Maker runs but doesn't produce ice, there could be several reasons: * Check that the unit has a water supply. * Ensure the water sump overflow tube is correctly positioned. * If the thermistor is faulty, replace it. * If none of these steps work, the control board could be the problem, and you may need to call for service.
  • C
    Christopher VincentAug 14, 2025
    What to do if my Manitowoc Sotto UG-40 Ice Maker does not run?
    • M
      Martin ClineAug 15, 2025
      If your Manitowoc Ice Maker doesn't run, the issue might stem from a lack of power. Check if the breaker is off, a fuse is blown, or if the unit is unplugged. Restore power to resolve this. Another cause could be that the toggle switch isn't in the ice position; make sure to place it correctly. Also, if the storage bin is full, remove some ice and wait three minutes.
  • E
    Eric HughesAug 20, 2025
    How to fix shallow or white ice cubes in my Manitowoc Sotto UG-40?
    • J
      Jennifer FaulknerAug 20, 2025
      If your Manitowoc Ice Maker produces shallow, incomplete, or white ice cubes, it could be due to several factors. The ice machine might be dirty, so try de-scaling and sanitizing it. Also, verify that the water pressure supply is correct. High air temperature around the ice machine can also be a factor, so ensure proper ventilation or consider moving the unit. Finally, check if the dip switch is correctly adjusted.
  • K
    karina35Aug 25, 2025
    Why is the freeze cycle long with low production in my Manitowoc Sotto UG-40 Ice Maker?
    • C
      christinariosAug 25, 2025
      If your Manitowoc Ice Maker's freeze cycle is long and production is low, the condenser may be dirty; try cleaning it. Also, high water temperature can cause this issue, so connect the machine to a cold water supply and check the check valves in faucets and other equipment. If these steps don't resolve the problem, there might be a refrigeration issue, and you should call for service.
  • D
    deborahalvaradoAug 30, 2025
    What to do if ice cubes do not release from my Manitowoc Ice Maker?
    • C
      Corey WheelerAug 30, 2025
      If the ice cubes in your Manitowoc Ice Maker do not release, it could be due to a dirty machine. Try descaling and sanitizing it. Low ambient temperature around the ice machine may also be the cause, so move it to a warmer area. Additionally, check if the dip switch is incorrectly adjusted, making the cubes too large; adjust the dip switch accordingly.
  • J
    Joseph LamSep 4, 2025
    Why won't my Manitowoc Sotto UG-40 Ice Maker initiate a harvest cycle?
    • J
      Jose DuncanSep 4, 2025
      If your Manitowoc Ice Maker will not initiate a harvest cycle, the liquid line thermistor might be faulty; replace it. If that doesn't solve the problem, it could be a control board issue, and you should call for service.

Manitowoc Sotto UG-40 Specifications

General IconGeneral
ModelSotto UG-40
TypeUndercounter Ice Maker
Condenser TypeAir-cooled
RefrigerantR134a
Ice TypeGourmet
Dimensions (H x W x D)33.5 x 19.75 x 24.5 inches
Power Supply115V/60Hz/1Ph
Water Connection3/4"