20 Part Number: 040006977 09/22
Maintenance Section 4
Exterior Cleaning
Clean the area around the ice machine as often as necessary
to maintain cleanliness and efficient operation.
Sponge any dust and dirt off the outside of the ice machine
with mild soap and water. Wipe dry with a clean, soft cloth.
A commercial grade stainless steel cleaner and polish may be
used.
Removal from Service/Winterization
GENERAL
Special precautions must be taken if the ice machine is to
be removed from service for an extended period of time or
exposed to ambient temperatures of 0°C (32°F) or below.A
dirty condenser restricts airflow, resulting in excessively high
operating temperatures. This reduces ice production and
shortens component life. Clean the condenser at least every
six months. Follow the steps below.
,
Caution
If water is allowed to remain in the ice machine in freezing
temperatures, severe damage to some components could
result. Damage of this nature is not covered by the warranty.
Follow the applicable procedure below.
AIR‑COOLED ICE MACHINES
1. Disconnect the electric power at the circuit breaker or
the electric service switch.
2. Turn off the water supply.
3. Drain the water from the water sump and water pump
by disconnecting the water pump tubing.
4. Disconnect and drain the incoming ice-making water
line and disconnect the tubing from the water inlet valve
outlet and allow water to drain.
5. Blow compressed air in the drain opening and water
valve outlet hose, then reattach.
6. Make sure water is not trapped in any of the water or
drain lines.