132 Part Number 000014797 Rev02 05/18
Normal Operation
Example below is for normal operation at 86°F (30°C) air
temperature 68°F (20°C) water temperature.
FREEZE CYCLE
Normal suction line temperature at the compressor
will range from 86°F (30°C) three minutes into the
cycle to 8°F (-13°C) at the end of the freeze cycle.
Normal discharge line temperature at the compressor
will range from 168°F (76°C) to 140°F (60°C) through
the freeze cycle.
HARVEST CYCLE
Suction line temperature at the compressor will range
from 64°F (18°C) to 111°F (44°C) through the harvest
cycle. An obstructed capillary tube will not effect suction
line temperature range during the harvest cycle. Low
refrigerant charge will have a lower temperature than
normal.
Discharge line temperature at the compressor will range
from 180°F (82°C) to 150°F (60°C) through the harvest
cycle.
Ice fill pattern will vary depending on severity of the
obstruction or refrigeration loss. Ice fill patterns will range
from no ice on the entire evaporator to thin only at the
evaporator outlet (thin at the bottom, thick at the top of
the evaporator).

Table of Contents

Other manuals for Manitowoc URF0140A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc URF0140A and is the answer not in the manual?

Manitowoc URF0140A Specifications

General IconGeneral
BrandManitowoc
ModelURF0140A
CategoryIce Maker
LanguageEnglish

Related product manuals