EasyManuals Logo
Home>Manitowoc>Ice Maker>URF0140A

Manitowoc URF0140A Technician's Handbook

Manitowoc URF0140A
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
Part Number 000014797 Rev02 05/18 203
4. Recovered refrigerant must come from a
contaminant-free” system. To decide whether the
system is contaminant free, consider:
Type(s) of previous failure(s)
Whether the system was cleaned, evacuated and
recharged properly following failure(s)
Whether the system has been contaminated by
this failure
Compressor motor burnouts and improper past
service prevent refrigerant re-use.
Refer to “Recovery and Recharging Procedures
UDE065/UDE080” on page 207 to test for
contamination.
5. “Substitute” or “Alternative” Refrigerant
Must use only Manitowoc-approved alternative
refrigerants.
Must follow Manitowoc-published conversion
procedures.

Table of Contents

Other manuals for Manitowoc URF0140A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc URF0140A and is the answer not in the manual?

Manitowoc URF0140A Specifications

General IconGeneral
BrandManitowoc
ModelURF0140A
CategoryIce Maker
LanguageEnglish

Related product manuals