4. Recovered refrigerant must come from a
contaminant-free” system. To decide whether the
system is contaminant free, consider:
Type(s) of previous failure(s)
Whether the system was cleaned, evacuated and
recharged properly following failure(s)
Whether the system has been contaminated by
this failure
Compressor motor burnouts and improper past
service prevent refrigerant re-use.
Refer to “Recovery and Recharging Procedures
UDE065/UDE080” on page 207 to test for
contamination.
5. “Substitute” or “Alternative” Refrigerant
Must use only Manitowoc-approved alternative
refrigerants.