54 Part Number 000014797 Rev02 05/18
D. Remove the Ice Thickness Probe
Compress the side of the ice thickness probe near the
top hinge pin and remove it from the bracket.
NOTE: At this point, the ice thickness probe can easily
be cleaned. If complete removal is desired follow the ice
thickness probe wire to the bulkhead grommet (exit point)
in the back wall. Pop the bulkhead grommet out of the
back wall by inserting fingernails or a flat object between
the back wall and the grommet and prying forward.
Pull the bulkhead grommet and wire forward until the
connector is accessible, then disconnect the wire lead from
the connector.
Ice Thickness Probe Cleaning
• Mix a solution of Manitowoc ice machine cleaner and
water (2 ounces of cleaner to 16 ounces of water) in a
container.
• Soak the ice thickness probe a minimum of 10 minutes.
Clean all ice thickness probe surfaces and verify the ice
thickness probe cavity is clean. Rinse thoroughly with clean
water, then dry completely. Incomplete rinsing and drying
of the ice thickness probe can cause premature harvest.

Table of Contents

Other manuals for Manitowoc UYF0140A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc UYF0140A and is the answer not in the manual?

Manitowoc UYF0140A Specifications

General IconGeneral
BrandManitowoc
ModelUYF0140A
CategoryIce Maker
LanguageEnglish

Related product manuals