EasyManua.ls Logo

Manitowoc UYF0310A - Page 143

Manitowoc UYF0310A
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part Number 000014797 Rev02 05/18 143
Discharge Line Temperature High Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 136
Restricted Condenser Air Flow
• High inlet air temperature
• Condenser discharge air re-circulation
• Dirty condenser fins
• Defective fan cycling control
• Defective fan motor
Improper Refrigerant Charge
• Overcharged
• Non-condensible in system
• Wrong type of refrigerant
Other
• Non-Manitowoc components in system
• High side refrigerant lines/component restricted
(before mid-condenser)
Freeze Cycle Discharge Temperature Low Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 136
Improper Refrigerant Charge
• Undercharged
• Wrong type of refrigerant
Other
• Non-Manitowoc components in system
• High side refrigerant lines/component restricted
(before mid-condenser)
• Defective fan cycle control
NOTE: Do not limit your diagnosis to only the items listed
in the checklists.

Table of Contents