43
A) – Water inlet from the pump
B) – Water outlet to return nozzle
C) – Waste water outlet
Connection without skimmer – top hole – hose from ltration into the pool; Bottom
hole – Hose from pool to ltration
ATTENTION: When installing solar panel, UV lamp and chlorinator in the ltration
circuit they must be connected behind the ltration device, for instance pool - l-
tration -solar panel - pool.
ATTENTION: Finer sizes of ltration sand may appear in the pool in the beginning
of ltration cycle. This eect depends on quality of ltration sand and will disappe-
ar as soon as these ne particles are washed out of the lter. This is not a defect of
ltration unit.
Initial operation
Once the ltration vessel has been lled with sand ll and hoses have been connec-
ted according to the description above and system fully watered, the process of ini-
tial rinsing can be started to put the ltration unit into operation. Switch the ltra-
tion unit on and wait till it starts to suck the water. When the pump sucks water, the
backwashing process can be started. If necessary repeat the backwashing process.
FILTRATION
ATTENTION: Due to safety reasons and prevention of ooding of ltration unit
check after connecting all the joints and sealing if seat well and seal correctly.
Water from pool should circulate over the pump at least 3 to 5 times depending
on system size and load. The necessary time depends on ltration capacity and
pool size. When the pool is used intensively or with unusual pollution the opera-
tion period of the ltration unit must be prolonged.
Impurities from circulating water are captured in the sand ll of the ltration
unit. If you add occulant the ltering ability will grown and at the same time the
consumption of water improvement agents will be reduced.
BACKWASHING
Switch the pump motor o.
Set the six-way valve in the position >>4<< “Backwashing”
Switch the pump motor on, after 5 minutes of backwashing the lter will be clean.
Check visually the waste pipe outow.
Switch o the pump motor.
Set the six-way valve to the position >>2<< “Rinsing”
Switch on the pump motor.
Next 30 seconds the chamber for clean water is being rinsed to the waste pipe.
Switch o the pump motor.
Set the six-way valve to the position >>1<< “Filtration
Switch on the pump motor.
The ltration system is prepared for further operation. Note the value on pressure gauge.