5.3.2.- Coffee dosage setting.
The grinder is set at the factory
for a grinding time of 1.8 seconds for 1
cup of coffee and 3.1 seconds for 2
cups of coffee. If the dose obtained is
not what you want in your coffee
machine, modify the dose as follows:
- Press the 1 cup key (Pos. F) for 1.5
seconds until the message “C1:
1.80” appears on screen.
- Press the keys “–” or “+” (Pos. B, C)
until reaching the desired value.
- Press the 1 cup key again to confirm the new dose.
- Perform the same operation with the 2 cup key (Pos. G).
Program in first place the dose for 1 cup. Notice that the dose for 2 cups
is limited to double of the programmed dose for 1 cup.
5.3.3.- Filter-holder detection system setting.
The grinder has several systems for selecting 1 or 2 cup doses, which may
be programmed by your Technical Assistance Service:
- Automatic filter-holder identification. (Factory
programmed setting.) This patented system
automatically detects 1-cup or 2-cup filter-
holders.