MR6100 Serial UHF reader user manualVer 1.0)◣
Address
Floor 3/5, Block D,Changyuan New Material Port, No 2 Central 1st Hi-tech Av., Nanshan Shenzhen, P.
R.C. Post518057
Phone0755-2654 6392 FAX0755-2655 3743
E-mailtechnical@marktrace.com Websitewww.marktrace.com
17
configure between 10-990msWhen in trigger working mod, reading
maximum lasting time can be configure as 255s
2Read tag type can be 18000-6B or EPC G2also can be configure read both
at same timeexpand function);
3When read EPC tagread area can select as EPCTID or USER memory
6B tag cannot select area
4User can select read tag‟s start address and read data lengthEPC tag data
use word as unit6B tag data use byte as unit;
5User filter repeat tagFilter set one slide time windowonly new data which
not show in box can be buffer or direct output
6Read tag data can be select buffer or directly outputdata buffer adapt with
power down save ferroelectric memorystorage capacity 32KByteswhen read
data length is 12Bytescan store more than 2200pcs tag data
3output configuration
1In working mode configure, when select data output as directly output mode,
user can configure output port
2Reader data output port have RS232RS485WiegandEthernet and relay
output
3Wiegand protocol support Wiegand26 and Wiegand34
4Relay close delay time configurable between 0-99s
5For above mentioned port, user can select one type or multiple type to
output data
6Data output can in ASCII code and Hex formatdata format see below