EasyManua.ls Logo

Martin SB6000 - Trim and Door Installation; Non-Combustible Facing Installation; Mantel Installation Guidelines; Glass Door Installation

Martin SB6000
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL
ACE
COMBUSTIBLE FRAMING
COMBUSTIBLE FRAMING
MEMBERS FACING MATERIAL
MEMBERS FACING MATERIAL
TO TOP OF SPACERS.
TO TOP OF SPACERS.
CAUTION: DO NOT COVER 
CAUTION: DO NOT COVER 
OR RESTRICT SIDE VENT 
AREAS WITH SURROUND 
AREAS WITH SURROUND 
OR TRIM MATERIALS.
OR TRIM MATERIALS.
USE ONLY NON-COMBUSTIBLE
USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP OF SPACERS.
MATERIALS BELOW TOP OF SPACERS.
NON-COMBUSTIBLE
NON-COMBUSTIBLE
FACING MATERIAL
FACING MATERIAL
FIREPLACE
FACE
STEEL LINTEL
(OPTIONAL)
(OPTIONAL)
WARNING:
WARNING:
THE SPACE BETWEEN THE
THE SPACE BETWEEN THE
FACE OF THE FIREPLACE
AND THE NON-COMBUSTIBLE
AND THE NON-COMBUSTIBLE
FACING MATERIAL MUST
FACING MATERIAL MUST
MUST BE SEALED. FAILURE
MUST BE SEALED. FAILURE 
TO PROPERLY SEAL THIS 
TO PROPERLY SEAL THIS 
CRACK CAN CAUSE A 
POSSIBLE FIRE HAZARD AND
POSSIBLE FIRE HAZARD AND
WILL VOID THE WARRANTY.
WILL VOID THE WARRANTY.
FIGURE 25
25
GLASS DOOR INSTALLATION
This fireplace has been tested and listed for use with optional Model WSB60 glass doors. For installation of
the Model WSB60 glass doors, see the instructions provided with the doors.
TRIM AND DOOR INSTALLATION
FIGURE 26
53D9027. Rev 1 03/03
COMBUSTIBLE
SURROUND
PLACEMENT
COMBUSTIBLE SURROUND MATERIALS 
COMBUSTIBLE SURROUND MATERIALS 
MAY BE PLACED INSIDE THE SHADED 
MAY BE PLACED INSIDE THE SHADED 
AREAS. COMBUSTIBLES MAY NOT 
AREAS. COMBUSTIBLES MAY NOT 
OVERLAP EDGE OF BLACK PAINTED 
OVERLAP EDGE OF BLACK PAINTED 
FACE MORE THAN 1/8".
FACE MORE THAN 1/8".
DO NOT RESTRICT 
SIDE AIR INLETS
2 1/2"
(REF.)
EXTEND LINE FROM OPPOSITE
EXTEND LINE FROM OPPOSITE
REAR CORNER OF FIREBOX
REAR CORNER OF FIREBOX
PAST INSIDE OPENING OF THE
PAST INSIDE OPENING OF THE
FRONT FACE SIDE PANEL.
FRONT FACE SIDE PANEL.
OUTLINE OF
FIREPLACE
FIREBRICK
TOP EDGE OF FIREPLA
OP EDGE OF FIREPLA
CE
CE
COMB
COMB
USTIBLE MANTEL
USTIBLE MANTEL
USE ONL
USE ONL
Y 
Y 
NON-COMB
NON-COMB
USTIBLE
USTIBLE
MA
MA
TERIALS BELO
TERIALS BELO
W
W
TOP OF SP
OP OF SP
ACERS
CERS
COMB
COMB
USTIBLE FRAMING
USTIBLE FRAMING
MEMBERS
MEMBERS
TO
O
TOP OF SP
OP OF SP
ACERS
CERS
12"
12"
MAX
MAX
18" MIN.
18" MIN.
FR
FR
OM FIREPLA
OM FIREPLA
CE OPENING
CE OPENING
TO BO
O BO
TT
TT
OM OF COMB
OM OF COMB
USTIBLE MANTEL.
USTIBLE MANTEL.
TO BO
O BO
TT
TT
OM OF COMB
OM OF COMB
USTIBLE MANTEL.
USTIBLE MANTEL.
(MANUF
(MANUF
ACTURER RECOMMEND
CTURER RECOMMEND
ATION)
TION)
TOP EDGE OF
OP EDGE OF
FIREPLA
FIREPLA
CE OPENING
CE OPENING
MANTEL INSTALLATION
NOTE: IF MODEL WSB60 GLASS DOORS
NOTE: IF MODEL WSB60 GLASS DOORS
ARE TO BE USED, NON-COMBUSTIBLE
ARE TO BE USED, NON-COMBUSTIBLE
TRIM ATTACHED TO THE FACE OF THE
TRIM ATTACHED TO THE FACE OF THE
FIREPLACE MUST NOT EXTEND OVER
FIREPLACE MUST NOT EXTEND OVER
THE SCREEN COVER AT THE TOP OF 
THE SCREEN COVER AT THE TOP OF 
THE FIREBOX OPENING. THE SCREEN
THE FIREBOX OPENING. THE SCREEN
COVER WILL HAVE TO BE REMOVED 
COVER WILL HAVE TO BE REMOVED 
BEFORE MODEL WSB60 GLASS DOORS
BEFORE MODEL WSB60 GLASS DOORS
CAN BE INSTALLED. NON-COMBUSTIBLE
CAN BE INSTALLED. NON-COMBUSTIBLE
TRIM MUST NOT EXTEND OVER EACH
TRIM MUST NOT EXTEND OVER EACH
SIDE OF THE FIREPLACE INTO THE
SIDE OF THE FIREPLACE INTO THE
FIREBOX OPENING TO AVOID INTER-
FIREBOX OPENING TO AVOID INTER-
FERENCE WITH INSTALLATION OF THE
FERENCE WITH INSTALLATION OF THE 
MODEL WSB60 GLASS DOORS.
MODEL WSB60 GLASS DOORS.