14
Problem Possible Cause Remedy
Unit too warm or too cold inside. Control set too warm or cold•
Airflow to front grille blocked.•
Excessive usage or prolonged door •
openings.
Door gasket not sealing properly.•
Adjust temperature colder or •
warmer as required. Allow 24
hours for temperature to stabilize.
Airflow must not be obstructed to •
front grille. See “clearances” on
page 3.
Allow temperature to stabilize for •
at least 24 hours.
Adjust or replace door gasket.•
Noise or Vibration Unit not level•
Water line tubing vibration.•
Level unit, see “Leveling Legs” on •
page 3.
Adjust the tubing as necessary to •
eliminate unwanted vibrations.
Unit will not run. Unit turned off•
Power cord not plugged in.•
No power at outlet.•
Turn unit on. See “Set the tempera-•
ture control” on page 4.
Plug in power cord.•
Check house circuit.•
Moisture collects on outside surface of
cabinet.
Hot and humid conditions.• Extremely hot and humid condi-•
tions can cause condensation on
outside of the cabinet. As humidity
and/or temperature decreases, the
condensation will disappear.
Moisture collects on inside of the unit. To many door openings.•
Prolonged door openings.•
Hot and humid conditions•
Limit the amount of door open-•
ings.
Limit the amount of time with the •
door open.
Extreme hot and humid conditions. •
Move unit to a controlled environ-
ment.
TROUBLESHOOTING YOUR ICE MACHINE