POSITIONING YOUR FREE-STANDING WOODFIRE
Free-standing woodfires must not be installed in a fireplace or alcove, or under a ceiling of less than
2.3m height. No wall or other fixed object may be closer to the front of the woodfire than one metre.
When fitting a water heating tube, the woodfire should be close to the water cylinder (See page 9).
Determine the installation position for your woodfire only after considering the necessary clearances
(See Tables below) and checking the practicability of installing the flue system. Regard heat resistant
walls with heat sensitive surface treatments (e.g. wallpaper or heat sensitive paints) as heat sensitive
walls. The flue shielding and the 25mm outer clearance gap above the ceiling will occupy a diameter
of 300mm (Grandview and Toronto 325mm), and this space must be available without the removal of
structural beams. Flue installations other than strictly vertical ones are possible. See AS/NZS 2918 for
information on non-vertical flues and flues passing through walls and eaves.
NEW ZEALAND — MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm) ‡
Model Flue Heat Shield
A B C D E F R§
Horizon & YES - 1200mm ¶ 50 300 220 578 50 355 500
LE 2000 NO 300 300 470 578 150 455 645
Siena YES - 1200mm ¶ 100 250 270 528 50 355 500
NO 360 250 530 528 230 535 760
LE 3000 & YES - 1200mm ¶ 75 300 300 630 50 405 575
LE 5000 NO Not Tested
Verona YES - 1200mm ¶ 125 300 345 630 125 480 680
NO Not Tested
Toronto YES - 900mm ¶ 125 400 320 730 50 425 600
NO 475 400 670 730 300 675 955
Grandview YES - 900mm ¶ 200 350 395 730 50 458 650
NO 450 350 645 730 250 658 930
¶ All Flue Heat Shields polished stainless steel with top heat dispersal cap.
See note under minimum New Zealand floor protector dimension table (page 5).
AUSTRALIA
MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm)
‡
WITH THE APPROPRIATE FLUE HEAT SHIELD
Model
A B C D E F R §
Horizon 150* 350 320* 628 100 405 575
LE 2000 125 325 295 603 100 405 575
Siena (with flue shield) 150 250 320 528 100 405 575
Siena (without flue shield) 360 250 530 528 230 535 760
LE 3000 and LE5000 150* 325 375* 655 125 480 680
Verona 250† 300 470† 630 125 480 680
Toronto 125 350 320 680 100 475 675
Grandview 150 350 345 730 100 508 720
‡, §, *, , †
— See next page.