* May be reduced by 25mm if a polished stainless steel flue shield is fitted instead of an enamelled one.
May be reduced by 50mm if a polished stainless steel flue shield is fitted instead of an enamelled one.
† May be reduced by 125mm if a polished stainless steel flue shield is fitted instead of an enamelled one.
§ Valid only when the room walls are at 90° to each other.
Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact the
relevant manufacturer for their specification. Masport accepts no responsibility for the deterioration of
surfaces or finishes.
See INSTALLING THE FLUE for recommended Australian flue systems.
FLOOR PROTECTOR (Hearth) REQUIREMENTS — Free - standing models
Unless your woodfire will be standing on an un-covered fireproof floor (containing no combustible
material) extending at least 500mm from the appliance, it will be necessary to provide a floor pro-
tector (hearth). See page 7 for construction details. Where the minimum size requirements bring the
side of the floor protector nearly to a wall, it is advisable to extend the protector to meet the wall.
K
J
W
Heat sensitive wall
C
L
A
G
H
Gl ass
540 min.
Minimum Floor
Protector Dimensions
Minimum allowable
'A' dimensions are
shown on page 4.
S
# Dimensions in the table are
valid only when the fire is exactly at
its minimum allowable wall clearance.
#
(565 min. for
Grandview & Toronto)
#
\
NEW
ZEALAND
A # C # G H J K L W S #
Ash
Floor
Prot.
Insul
Floo
r
Prot.
Flue Shield Flue Shield Flue Shield
YES NO YES NO YES NO Ø Ø
Horizon, LE 2000
50 300 220 470 170 435 555 160 300 875 785 1035 Yes Yes
Siena
100 360 270 530 170 490 555 160 300 875 890 1150 Yes Yes
LE 3000
75 300 225 490 660 138 420¥ 935 985¥ No Yes
LE 3000 with ash shelf
75 300 225 490 660 138 300 935 865 Yes Yes
LE 5000
75 300 225 490 660 138 300 935 865 Yes Yes
Verona
125 345 220 560 660 140 300 940 985 Yes Yes
Toronto
125 475 320 670 195 540 660 153 300 965 965 1315 Yes Yes
Grandview
200 450 395 645 195 610 760 103 520¥ 965
1330
¥
1580
¥
No Yes
¥ Increase by 80 mm if the floor protector top is not at least 50 mm above the floor.
ø See page 7 for minimum constructional requirements.
# Valid only when the fire is exactly at its minimum allowable wall clearance.
NOTE: Where a fan is being fitted, you may prefer to increase the ‘A’ dimension to 100 mm to
provide easier access for servicing. If so, the amount you add to ‘A’ to bring it to 100 mm must also be
added to the ‘C’ and ‘S’ dimensions.