OPERATOR’S
INSTRUCTION MANUAL
MAS830
MAS830L
DIGITAL MULTIMETER
SAFETY INFORMATION
This multimeter has been designed according to IEC
1010 concerning electronic measuring
instruments with an overvoltage category (CAT
) and pollution 2.
Follow all safety and operating instructions to ensure that the meter is used safely and is kept in
good operating condition.
Full compliance with safety standards can be guaranteed only with test leads supplied. If necessary,
they must be replaced with the type specified in this manual.
SAFETY SYMBOLS
Important safety information, refer to the operating
manual.
Dangerous voltage may be present.
Earth ground.
Double insulation (Protection class II).
Fuse must be replaced with rating specified in the
manual.
CAT II
Measurement category II, it is for measurements
performed on circuits directly connected to the low
voltage installation.
MAINTENANCE
Before opening the case, always disconnect test leads from
all energized circuits.
For continue protection against fire; replace fuse only with
the specified voltage and current ratings:
F 200mA/250V(Quick Acting)
Never use the meter unless the back cover is in place and
fastened completely.
Do not use abrasives or solvents on the meter. To clean it
using a damp cloth and mild detergent only.
-1-

Other manuals for Mastech MAS830L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mastech MAS830L and is the answer not in the manual?

Mastech MAS830L Specifications

General IconGeneral
DC Voltage Range200mV/2V/20V/200V/600V
AC Voltage Range200V/600V
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/2MΩ
Continuity BuzzerYes
Diode TestYes
Transistor TestYes
Power Supply9V battery
DisplayLCD
DC Current Range200μA/2mA/20mA/200mA/10A
Dimensions138mm x 69mm x 31mm