Do you have a question about the Mastech MY64 and is the answer not in the manual?
Type | Digital Multimeter |
---|---|
Diode Test | Yes |
Continuity Test | Yes |
Continuity Buzzer | Yes |
Battery Type | 9V battery |
Display | 3.5 digit LCD |
DC Voltage Range | 200mV to 1000V |
AC Voltage Range | 200V/750V |
DC Current Range | 200µA to 10A |
Resistance Range | 200Ω to 20MΩ |
DC Voltage Accuracy | ±(0.5% + 2 digits) |
DC Current Accuracy | ±(1.0% + 2 digits) |
Resistance Accuracy | ±(0.8% + 2 digits) |
Power Supply | 9V battery |
Disconnect leads, open case, unscrew, and heed static discharge warnings.
Carefully lift out the battery and circuit board from the multimeter.
Locate, remove the old fuse, and install the correct 200mA replacement fuse.
Guide the circuit board and battery back into their respective positions.
Start and tighten case screws, ensuring jack and switch alignment.
Snap case closed, finish tightening screws, and perform an ohms test.