- Overload Protection: 250V DC or AC rms
- Max. Input Voltage: 200mV
- Frequency Range: 40 to 400Hz
- Response: Average, calibrated in rms of sine wave.
3.2.6 AC Current (with clamp, optional)
Range
Resolution
Accuracy
0.1mV/0.1A
±(1.5 % of rdg
+5 digits)
meter
200A
0.1A /0.1mV
Typical
±(3.0 %)
±(1.5 % of rdg
±3 digits)
Typical
±(3.0 %)
AC Clamp
AC Clamp
meter
0 to 200A
2000A
0 to 2000A
1mV/1A
1A/1mV
3.2.7 Resistance
Range
Resolution
Accuracy
±(1.0% of rdg + 3 digits)
±(1.0% of rdg + 1 digit1)
±(1.0% of rdg + 5 digits)
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
0.1Ω
0.001kΩ
0.01kΩ
0.1kΩ
0.001MΩ
0.01MΩ
- Open Circuit Voltage: 0.25V
- Overload Protection: 250V DC or AC rms
- Overload Protection:
20nF~20μF Ranges: F 200mA/250V fuse (quick acting),.
200μF/1000μF Ranges: No Overload Protection.
3.2.9 Capacitance
Range
Resolution Function
0.01nF
0.1nF
0.001μF
20nF
200nF
2μF
0.01μF
0.1μF
1μF
20μF
200μF
1000μF
±(4.0% of rdg + 10digits)
±(4.0% of rdg + 3digits)
- Open circuit voltage: approx. 0.5V
- Overload Protection: 250V DC or AC rms
3.2.8 Temperature
Range
-20 to 1000˚C ˚C
Resolution
1˚C
Accuracy
-20 to 0 ˚C ˚C
0 to 400˚C ˚C
400 to 1000˚C ˚C
±(5% of rdg + 4digits)
±(1% of rdg + 3digits)
±(2% of rdg + 3digits)
Range
-0 ~1800˚F ˚F
Resolution
1˚F
Accuracy
-0 ~50˚F ˚F
50 ~750˚F ˚F
750 ~1800˚F ˚F
±(5% of rdg + 4digits)
±(1% of rdg + 3digits)
±(2% of rdg + 3digits)
- Overload Protection: 250V DC or AC rms