MS8211D
DIGITAL MULTIMETER
INSTRUCTION MANUAL
Question and Answer IconNeed help?

Do you have a question about the Mastech MS8211D and is the answer not in the manual?

Mastech MS8211D Specifications

General IconGeneral
TypeDigital Multimeter
DisplayLCD
Data HoldYes
Continuity BuzzerYes
Operating Temperature0°C to 40°C
Measurement FunctionsAC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Continuity, Diode Test
AC Voltage Range0-750V
DC Voltage Range0-1000V
Resistance Range0-20MΩ
Capacitance Range0-100μF
Frequency Range0-10MHz
Battery9V

Summary

Safety Information

Preliminary Safety Checks

Ensures user observes safety rules and checks meter condition before use.

Safe Operation During Use

Provides guidelines for safe operation, including selecting ranges and avoiding contact.

Understanding Safety Symbols

Explains critical safety symbols and measurement category indicators used in the manual.

Maintenance and Care

Covers essential maintenance procedures, battery replacement, and safe storage practices.

Digital Multimeter Description

Names Of Components

Identifies and lists all the physical parts and controls of the digital multimeter.

Components Elucidation

Details the function and operation of each button, switch, and display element.

Specifications

General Specifications

Outlines environmental conditions, power, dimensions, and general operating parameters.

Electrical Specifications

Provides detailed ranges, accuracy, overload protection, and input impedance for measurements.

Operating Instructions

Data Hold Function

Explains how to freeze the current reading on the display and disable auto power-off.

Maximum Value Measuring And Hold

Describes the function to measure and hold the peak value during voltage measurements.

Function Transform

Details how to switch between different measurement modes like voltage, resistance, and current.

Range Transform

Explains the use of auto and manual ranging for voltage and resistance measurements.

Auto Power Off Feature

Informs about the meter's automatic power-down feature and how to disable or reset it.

Preparation For Measurement

Guides on selecting the correct range and connecting probes before taking measurements.

Measuring DC Voltage

Provides step-by-step instructions and safety precautions for measuring DC voltage.

Measuring AC Voltage

Details the procedure and safety warnings for measuring AC voltage accurately.

Measuring Resistance

Explains how to measure resistance, including precautions for in-circuit testing.

Testing Diode

Guides on performing diode tests and interpreting the forward voltage drop readings.

Continuity Test

Describes how to check circuit continuity, including the audible buzzer function.

Measuring DC Current

Provides instructions for safely measuring DC current in a circuit.

Measuring AC Current

Details the procedure and safety precautions for measuring AC current.

Logic Test

Explains how to test logic levels using LED indicators and LCD readings.

Maintenance

Battery Replacement

Instructions on how to safely replace the meter's batteries when the low battery indicator appears.

Test leads Replacement

Guidance on replacing test leads and clips to maintain safety and accuracy.

Accessories