TROUBLESHOOTING
Problem
Possible Solutions
Low heat, LP
gas
The
propane
regulator
assembly incorporates an excess
flow
device designed to
supply
the
grill
with
sufficient
gas
flow
under
normal
conditions,
yet
control excess
gas
flow.
Rapid changes in
pressure
can trigger the excess flow
device,
providing
a
low
flame and
low
temperature.lf the
tank valve is turned
open to allow
gas
flow while
a burner
valve is open, the surge
of
pressure
will
cause
the
device
to activate. The device will remain
closed
until the
pressure
is
equalized.
This
should occur within 5 seconds.
To
ensure this does not cause difficulty in lighting the
grill,
follow
these instructions:
1. Make sure all burner valves are
"OFF".
2. Open the tank valve
and
wait 5
seconds.
3.
Light
the burner one
at a
time following the lighting
instructions listed on the
control
box and Page 20.
Low heat, natural
gas
Gas
pressure
is
affected by
gas
line
and
length
of
gas
line
from house
gas
line. Follow the recommendations in the
chart below.
From House to Grill
Distance
Tubing Size
Up
to 25 foot
3/8 in. diameter
26-50 foot
/,
in. diameter
51-100 foot 213 in. of run 3/4 in.
1/3 in. of run
112
in.
Low heat
generated
with
Knob in
"Hl"
position
1. Make
certain the
problem
is isolated to only one burner.
lf it appears so, clean the orifice and burner, clearing
ports
of any obstruction.
2.
Check for a bent or
kinked fuel hose.
3. Make
sure
the air shutter is
properly
adjusted.
4. Check for
proper gas
supply
and
pressure.
5. Pre-heat the
grill
for a full 15
minutes.
6. lf using LP
gas,
check for an empty tank.
24