Troubleshooting
Problem: Unit Fails to Regenerate
Verify that electrical power is
getting to the outlet
Verify a minimum 30 psi inlet
water pressure
Insure that the drain line is free
of blockage
Plugged backwash flow control
Clean or replace the backwash
flow control
Incorrect P Value Programming
Reprogram with proper P Value
Problem: Poor Water Quality When Unit is in Service Position
The bypass valve is open or
defective
Insure that the bypass valve is in
the service position
Set the timer to regenerate more
often
See symptom: Loss of filter
media
Change in raw water quality
Test the raw water quality and
adjust regeneration frequency
Leak at the distributor tube
Verify that the distributor is flush
with the top of the tank
Problem: Loss of Filter Media
Backwash flow control is missing
or is the incorrect size
Verify that the proper backwash
flow control is installed
Verify that the well system is
operating properly