NOTE:
The meter has a process of initialization before it enters
non-contact AC voltage detection mode. During this process,
the meter will not respond if you press the "SELECT" key. Only
after the process finishes (the display shows " " and the
built-in buzzer does not sound) can you press the "SELECT"
key to change meter function.
Instruction for the "SELECT" Key
Press and hold down the "SELECT" key for about 3 secs to turn on
the meter. The meter enters Auto Check mode.
In Auto Check mode, press the "SELECT" key to step through the
functions:
Auto Check mode (default) continuity test
non-contact AC voltage detection AC voltage measurement
DC voltage measurement resistance measurement
frequency measurement capacitance measurement
Auto Check mode.
Pressing and holding down the "SELECT" key for about 3 secs will
turn off the meter.