OPERATION
16 May 2006 / WHISPER 3,5 / EN
3 OPERATION
3.1 GENERAL
The generating set is operational after full installation and
filling up with: fuel, engine lubricating oil and cooling liquid,
filling the starter battery with acid, connecting the battery
to earth and connecting the digital remote control panel.
1 Filling cap
2 Minimum oil level
3 Maximum oil level
Fig. 9:
3.2 OPERATING INSTRUCTIONS
3.2.1 Summarised operating instructions (daily
use)
Routine "pre-start" checks:
1 Check oil level (refer to fig. 9).
2 Engine cooling system (all valves open).
3 Power source selector switch (off/shore
power/generator power). Switch to power source
switch "OFF", or switch off all consumers in the usual
way. If a MASTERSWITCH is installed, this operates
automatically.
4 Switch on battery switch (when installed).
5 Fuel valve: open.
Starting:
Push the start button to initiate the full automatic
starting procedure. You can monitor the procedure on
the display.
In operation checks:
1 Check for abnormal noise or vibration
2 Check the voltage
3 Check sea water flow at exhaust outlet
4 Power source selector switch (off/shore
power/generator power). Switch to power source
generator. If a MASTERSWITCH is installed, this
operates automatically.
5 Before loading the generating set up to maximum,
have it run warm. Continuous load should be
restricted to 70 % of maximum load.
Stopping generator:
1 Switch off all electrical devices (consumers). If the
generating set has been running under full load for a
longer period, do not shut it down abruptly. Reduce
the electrical load to about 30% of the rated load (i.e.
30% of 3 kW is approx. 1000W) and let it run for
approx. 5 minutes.
2 Press the STOP button.
3 Close the inlet sea water cock.
4 Switch to an other 230V power source, if available. If
a Masterswitch is installed, this is done automatically.
3.2.2 Extended operating instructions
Check when starting the first time or after a longer period
of rest:
1 If there is any damage caused by transport or
installation.
2 Check if installation conforms to the installation
instructions.
3 Ensure the generating set is free to turn without
obstruction.
4 Check all hoses and hose connections for leaks.
5 Check all cables and cable end terminal connections.
6 Check the engine and generator mounting bolts.
Routine "pre-start" checks:
1 Check engine oil level.
The generator switches off in the event of insufficient
oil-pressure. Even when the oil level is too low the oil
pressure can be high enough. Do not run the
generator with the oil below the lowest mark in the,
because a smaller volume of oil will become
contaminated considerably quicker than a larger
volume. Therefore we recommend daily oil-checks.
Check oil level prior to starting the engine or at least 5
minutes after the engine has stopped.
2 Check sea water cocks. Do not forget the valve of the
water outlet in case of a water/exhaust gas separator.