• All interconnected alarms must be connected to the same sub/circuit
• A common Neutral must be used for interconnect to function
• Do not connect the interconnect wires to Active or Neutral
Status Description
Status Indication Description
Standby status The Red LED ashes every 40
seconds, with no Green LED.
Operating under battery power
only.
AC power indication The Green LED is continuously
illuminated
The unit is operating under AC
power.
Low battery warning The unit chirps, with Red LED ash-
ing every 40 seconds.
Battery voltage is low – replace
battery
Self-test fault warning The Red LED ashes twice every
40 seconds.
The buzzer fault or buzzer
detection circuit fault.
End-of-life warning The unit chirps between the Red
LED ashing twice
The unit will send end-of-life warn-
ing after 10 years of operation.
Alarm must be replaced.
Test function The Red LED ashes once every
second, with alarm sounding until
the TEST button is released.
• Test by pressing the TEST button
on the smoke alarm for at least 5
seconds.
• The alarm will sound if all elec-
tronic circuitry, buzzer and battery
are working properly.
Silence function The Red LED ashes every 8
seconds.
• This smoke alarm has a built-in
Silence feature.
• If cooking or other
non-hazardous sources cause
the alarm to sound, it can be
temporarily silenced by pressing
the HUSH button for a minimum 2
seconds.
• The alarm enters silence mode
for 10 minutes.
• After the 10-minute dormant
period, the smoke alarm will
resume normal operation
Interconnection alarm Alarm sounds without Red LED
ashing.
Occurs when another
interconnected alarm is triggered.