7
a rm, at surface near the electrical equipment
and ensure proper ventilation.
7.1 Electrical safety:
•
Electric supply cables and connected equipment
must be in perfect condition.
•
The generator is to be operated only with
equipment whose voltage specications conform
with the generator's output voltage.
•
Never connect the generator to the power
supply (socket-outlet).
•
Keep the cable length to the electrical
equipment as short as possible.
7.2 Environmental protection
•
Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
•
Recycle packaging material, metal and plastics.
7.3 Connecting to earth
The housing is allowed to be connected to
earth in order to discharge static electricity. To
do this, connect one end of a cable to the earth
connection on the generator (Item 8) and the
other end to an external earth (for example an
earthing rod).
7.4 Topping up fuel
WARNING
Switch o and ensure you are in a well ventilated
area.
Use only a mixture of unleaded regular petrol
and special 2-stroke engine oil in a mixing ratio of
50:1.
Important: Do not use a dierent mixing ration
and do not use pure petrol.
Do not use fuel if it is more than 2-3 months old.
5. Layout and items supplied (Fig. 1-3)
1. Carry handle
2. Tank cover
3. Petrol cock
4. Starter cable
5. Motor cover
6. Choke lever
7. ON/OFF switch
8. Earthing connection
9. 1x 230 V~ socket
10. Screwdriver handle
11. Screwdriver insert
12. Spark plug wrench
13. Oil ller jug
14. DC oulet adapter cable
15. Voltmeter
16. 12 V d.c. outlet
17. Overload cut-out
18. Output adjustment
6. Technical data
Engine
Model: YK1E45F
Engine: 2-stroke engine.OHV,1 cylinder
Cubic capacity: 63 cm
3
Degree of compression: 6,8:1
Nominal speed: 3600 min
-1
Fuel tank volume: 2,0 l
Generator
Mains voltage (V): 230 V
Frequency (Hz): 50 Hz
Ampere (A): 3,7 A
Nominal power PRP (kW): 0,85
Power factor: 1,0
Power class: G1
Noise: 95 dB(A)
7. Before putting the generator into
operation
Remove the packaging material and check that all
items have been supplied. Place the generator on