4.2 MANAGER SCREEN DESCRIPTIONS
• P0: Maximum progam time -
Sets the total run time of any program.
• P1: Default workout time -
Workout time when QUICK START is pressed or when no time is
selected during program set up.
• P2: Default resistance level -
Starting resistance when QUICK START is pressed or no resistance
level is selected during program set up.
• P3: Default user weight -
Weight used for program calorie expenditure calculations.
• P4: Speed Units - Display value in miles or kilometers.
• P5: Machine Type -
Console is shared between the A5x and I5xi. A5x default setting is
“SWING” and I5xi default setting is “RAMP
”.
• P6: Console beep on / off - Confirmation beeps can be turned on or off.
• P7: Accumulated distance - Total distance of all programs.
• P8: Accumulated time - Total accumulated program time displayed in hours.
• P9: Display language -
Select between English, Spanish, French Italian, Dutch and German.
• P10: Software version -
Current version of software. Refer to this when calling Matrix Technical Service.
• P11: Incline calibration -
Default display is OFF. Selecting ON will automatically calibrate the
incline motor (s) to factory settings. Use this feature when actual
elevation does not match console display.
• P12: Incline Reset -
This is a software feature that resets machine elevation to 0 degrees
after 30 seconds of user inactivity. During incline reset, movement
can be stopped by pressing any console key. Display will scroll “HOLD
SELECT TO RESUME”. To resume reset to 0 degrees, hold “SELECT”key
for three seconds.
• P13: Default incline level -
Starting incline level at each program start except FIT TEST.
Factory setting is 10%. In FIT TEST, elevation is set to 0%
.
• P14: Error Code -
Console will record up to three errors. Error codes are stored permanently
unless reset by a technician. To reset error codes, hold MANUAL and
RANDOM keys for three seconds. Refer to these error codes when
calling Matrix technical service for assistance.
• P15: LCB Version -
Display will show LCB.VER XX YYY.
XX is machine type.
YYY is version number.
4.1 USING MANAGER MODE
• To enter manager mode, hold the UP and DOWN level keys for three
seconds until “MANAGER” appears on the middle LED display.
•
Press the UP and DOWN elevation keys to scroll between program screens.
• Press SELECT to modify program setting.
• Press UP or DOWN level keys to change value.
• Press QUICK START to save setting.
• Press QUICK START again to exit manager mode.
(example changing default time from 20:00 - 30:00 minutes).